The Agilent 6546 LC/Q‑TOF Mass Spectrometer with Agilent 1290 Infinity II Front End is a high‑resolution, accurate‑mass LC/MS platform designed for advanced qualitative and quantitative liquid chromatography–mass spectrometry applications. This integrated system combines the analytical power of the Agilent 6546 Quadrupole Time‑of‑Flight (Q‑TOF) MSD with the speed, precision, and robustness of the Agilent 1290 Infinity II UHPLC front end. The Agilent 6546 Q‑TOF delivers excellent mass accuracy, high sensitivity, and fast acquisition rates for confident compound identification, structural elucidation, and profiling. Paired with the 1290 Infinity II front end, the system supports ultra‑high‑pressure chromatography and high‑throughput workflows, making it ideal for complex samples and demanding analytical environments.

This refurbished Agilent 6546 LC/Q‑TOF with Agilent 1290 Infinity II Front End LC System has been fully tested and verified to be in proper working condition by Alliant Scientific

Includes:

  • Agilent 6546 LC/Q‑TOF Mass Spectrometer
  • Agilent 1290 Infinity II Front End System
    • Agilent 1290 Infinity II G7120A High‑Speed Pump
    • Agilent 1290 Infinity II G7116B Multicolumn Thermostat (MCT)
    • Agilent 1290 Infinity II G7167B Multisampler
      • Agilent G7167‑60101 InfinityLab Sample Thermostat
  • Agilent MS40+ RVP Roughing pump
  • Data System
  • 90 Day Warranty

Optional:

  • Agilent UHPLC Front End Systems (1260 Infinity Series)
  • Premium Refurbishment with Extended Warranty

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Agilent 6546 LC/Q‑TOF Mass Spectrometer — Specifications

  • Instrument Type: LC/MS
  • Mass Analyzer: Quadrupole Time‑of‑Flight (Q‑TOF)
  • Ionization Source: Electrospray Ionization (ESI)
  • Acquisition Modes:
    • Full‑scan accurate‑mass MS
    • MS/MS (tandem mass spectrometry)
  • Resolution: High‑resolution TOF analysis
  • Mass Accuracy: High mass accuracy for confident compound identification
  • Scan Speed: Fast acquisition suitable for UHPLC workflows
  • Sensitivity: Optimized for trace‑level detection
  • Software: Agilent MassHunter Workstation
  • LC Compatibility: Agilent 1260 and 1290 Infinity / Infinity II LC systems
  • Applications: Qualitative analysis, accurate‑mass identification, profiling, structural elucidation

Agilent 1290 Infinity II Front End System — Specifications

  • System Type: UHPLC Front End
  • Series: Agilent 1290 Infinity II
  • Design: Modular UHPLC configuration
  • Pressure Capability: UHPLC‑class high‑pressure operation
  • Performance: High flow accuracy, low dispersion, and excellent reproducibility
  • Integration: Designed for use with Agilent LC/MS and detector modules
  • Software: Agilent OpenLab CDS
  • Use Case: High‑speed, high‑resolution chromatographic separations

Agilent 1290 Infinity II G7120A High‑Speed Pump — Specifications

  • Pump Type: Binary high‑pressure mixing pump
  • Maximum Pressure: Up to 1300 bar
  • Flow Accuracy: High precision and reproducibility
  • Gradient Performance: Excellent gradient formation for fast separations
  • Compatibility: UHPLC and fast‑LC methods
  • Applications: High‑throughput UHPLC, LC/MS front‑end operation

Agilent 1290 Infinity II G7116B Multicolumn Thermostat (MCT) — Specifications

  • Module Type: Column thermostat
  • Function: Active column temperature control
  • Capacity: Supports multiple LC columns
  • Temperature Stability: High precision for reproducible retention times
  • Heating/Cooling: Thermostatted environment (with thermostat option when configured)
  • Applications: Method development, routine analysis, regulated workflows

Agilent 1290 Infinity II G7167B Multisampler

  • Injection Precision: High repeatability for quantitative analysis
  • Carryover: Low‑carryover design
  • Throughput: Optimized for fast UHPLC workflows
  • Pressure Capability: UHPLC‑compatible operation
  • Automation: Fully automated liquid sampling
  • Compatibility: Supports InfinityLab sample cooling and thermostat accessories
  • Vial Handling: Designed for high‑density sample batches

Agilent G7167‑60101 InfinityLab Sample Thermostat — Specifications

  • Accessory Type: Sample thermostat
  • Function: Temperature control for LC sample vials
  • Temperature Stability: Maintains consistent sample temperature
  • Integration: Designed for use with Agilent InfinityLab autosamplers
  • Purpose: Improves sample stability and reproducibility
  • Applications: Temperature‑sensitive sample analysis

Software Compatibility

  • Agilent MassHunter LC/MS software

Typical Applications

  • Pharmaceutical & biopharmaceutical analysis
  • Impurity and degradation studies
  • Metabolomics & lipidomics
  • Proteomics & biomolecule characterization
  • Environmental and food safety testing

 

Additional information

Availability

Condition

Brand

Onsite Installation

Model

, , ,

Warranty