Agilent 7890B GC with 5975C MSD, Wasson-ECE Dual TCD & 5 Sampling Valves

Listing #:LS-006868
Brand:
Model:5975C (G3170A), 7890B (G3440B)
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$39,500.00
In Stock
Make an Offer

Agilent 7890B GC with 5975C MSD, Wasson-ECE Dual TCD & 5 Sampling Valves — custom gas analysis system with a 5975C MSD, two TCDs, five rotary valves, and six columns. Refurbished and tested by Alliant Scientific.

Description

Agilent 7890B GC with 5975C MSD, Wasson-ECE Dual TCD & 5 Sampling Valves Overview

The Agilent 7890B GC with 5975C MSD, Wasson-ECE Dual TCD & 5 Sampling Valves is a gas analysis system built by Wasson-ECE Instrumentation on the Agilent 7890B platform. It combines an Agilent 5975C MSD (G3170A) with Triple-Axis Detector, two thermal conductivity detectors (TCDs), and a split/splitless (SSL) front inlet. Five rotary gas sampling and switching valves route gas samples through six columns.

The MSD identifies hydrogen cyanide, hydrogen sulfide, and carbonyl sulfide, each with a lower detection limit of 10 ppm. The TCDs identify hydrogen, methane, carbon monoxide, carbon dioxide, nitrogen, an oxygen/argon composite, ammonia, and water. Each TCD component has a lower detection limit of 0.1% (1,000 ppm).

The SSL front inlet feeds Column 1, a 60 m capillary column in the front programmable oven, which leads to the MSD. Column 2 is a capillary column in the back of the programmable oven. The remaining valves and columns sit in an auxiliary oven. Sample loops of 0.5 mL (V1, V3, V7) and 0.25 mL (V2) meter the gas samples. One TCD runs on nitrogen carrier gas and the other on helium carrier gas, each with its own electronic pressure control for reference and makeup flow.

The Agilent 5975C MSD (G3170A), also called the 5975C VL, is an electron ionization (EI) mass spectrometer with a diffusion pump. It uses a monolithic hyperbolic quadrupole mass filter with a mass range up to 1,050 u. Its Triple-Axis Detector raises signal intensity, reduces neutral noise, and extends detector life.

This Agilent 7890B GC with 5975C MSD, Wasson-ECE Dual TCD & 5 Sampling Valves is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 7890B Gas Chromatograph (G3440B)
    • Split/Splitless (SSL) Front Inlet
    • Two Thermal Conductivity Detectors (TCD)
    • Five Gas Sampling Valves
  • Agilent 5975C MSD (G3170A) with Triple-Axis Detector
    • Diffusion Pump
  • Data System
  • 90-Day Warranty

Looking for Another GC Configuration?

See our Agilent 7890B GC with Wasson-ECE Dual TCD & 4 Sampling Valves (no MSD), or browse our full Gas Chromatography inventory for other options.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies; custom configuration by Wasson-ECE Instrumentation
GC Model 7890B (G3440B)
MSD Agilent 5975C VL MSD (G3170A) with Triple-Axis Detector
MSD Ionization Electron ionization (EI)
MSD Vacuum System Diffusion pump
Mass Filter Monolithic hyperbolic quadrupole
Maximum Mass 1,050 u
Mass Axis Stability Better than 0.10 u over 48 hours
MSD Dynamic Range (Electronic) 10^6
MSD Components Detected Hydrogen cyanide, hydrogen sulfide, carbonyl sulfide
MSD Lower Detection Limit 10 ppm for each listed component
TCDs Two (TCD A on nitrogen carrier, TCD B on helium carrier)
TCD Components Detected Hydrogen, methane, carbon monoxide, carbon dioxide, nitrogen, oxygen/argon composite, ammonia, water
TCD Lower Detection Limit 0.1% (1,000 ppm) for each listed component
Inlet Inert split/splitless (SSL), front
Valves Five rotary gas sampling/switching valves (V1, V2, V3, V4, V7)
Sample Loops 0.5 mL (V1, V3, V7); 0.25 mL (V2)
Columns Six: 60 m capillary (code 2358, front programmable oven, to MSD); 10 m capillary (code 2428, back programmable oven); 8 ft K1; 15 ft K2S; 8 ft K1 + 10 ft K2S; 2 ft K2S
Carrier Gases Helium and nitrogen, 99.999%+ purity, 80 psig
Gas Sample Pressure Up to 400 psig
Sample-Wetted Lines Hastelloy tubing
Heating Control MSD transfer line: Thermal Aux #1 (back inlet); auxiliary oven: Valve Box A1; chase heater: Valve Box A2
Pneumatics Control Electronic Pneumatic Control (EPC), 0.001 psi pressure setpoint precision
Oven Temperature Range Ambient +4°C to 450°C
Power Requirements 120 VAC, 20 A
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

,

Onsite Installation

Warranty

Key Features

  • 5975C MSD Plus Dual TCD
    The MSD detects hydrogen cyanide, hydrogen sulfide, and carbonyl sulfide at 10 ppm, while the TCDs cover eight permanent gas and other components at 0.1%.
  • Five Rotary Valves
    Route gas samples through six columns to the MSD and the two TCDs.
  • Triple-Axis Detector
    Raises signal intensity, reduces neutral noise, and extends detector life.
  • Hastelloy Sample Path
    All sample-wetted lines are Hastelloy tubing, a corrosion-resistant alloy.
  • Dual Carrier Gas
    One TCD path runs on helium and the other on nitrogen, each with its own EPC reference and makeup control.
  • Auxiliary Oven
    Houses the valves and several columns, separate from the programmable main oven.

Applications

  • Sulfur and Cyanide Gas Analysis
    MSD detection of hydrogen sulfide, carbonyl sulfide, and hydrogen cyanide at 10 ppm.
  • Permanent Gas Analysis
    TCD detection of hydrogen, nitrogen, oxygen/argon, carbon monoxide, and carbon dioxide.
  • Ammonia and Water Analysis
    Detection of ammonia and water alongside permanent gases at a 0.1% lower detection limit.
  • Mass Spectral Confirmation
    EI mass spectra from the MSD support compound confirmation alongside TCD retention data.

FAQ (Frequently Asked Questions)

What is Wasson-ECE?

Wasson-ECE Instrumentation builds custom-configured GC analyzers on Agilent GC platforms, adding valves, columns, and auxiliary ovens to meet specific gas analysis needs.

What does the MSD detect?

The MSD identifies hydrogen cyanide, hydrogen sulfide, and carbonyl sulfide. Each has a lower detection limit of 10 ppm.

What do the TCDs detect?

The TCDs identify hydrogen, methane, carbon monoxide, carbon dioxide, nitrogen, an oxygen/argon composite, ammonia, and water. Each has a lower detection limit of 0.1% (1,000 ppm).

What is the difference between this system and the dual-TCD version without an MSD?

This configuration adds an SSL front inlet, a 5975C MSD (G3170A) with Triple-Axis Detector, and a fifth valve (V7) with a 0.5 mL loop. The MSD adds detection of hydrogen cyanide, hydrogen sulfide, and carbonyl sulfide at 10 ppm.

What gas purity and pressure does it need?

Helium and nitrogen at 99.999%+ purity and 80 psig. Gas samples can be introduced at up to 400 psig.

How many valves and columns does it have?

Five rotary valves and six columns.

Does this unit include a warranty?

Yes — this unit ships with a 90-day warranty.