Agilent 6890A Plus GC with 5973 MSD and CTC Analytics CombiPAL Autosampler — GC/MS system with S/SL and purged packed inlets, CO2 oven cooling, and a liquid, headspace, and SPME autosampler. Refurbished and tested by Alliant Scientific.

Description

Agilent 6890A Plus GC with 5973 MSD and CombiPAL Autosampler Overview

This system combines an Agilent 6890A Plus gas chromatograph, an Agilent 5973 mass selective detector (MSD), and a CTC Analytics CombiPAL autosampler for automated GC/MS analysis. The GC has one split/splitless (S/SL) inlet, one purged packed inlet, and a CO2 coolant valve for sub-ambient oven operation.

The 5973 MSD is a single quadrupole detector with electron ionization (EI). Mass range is 1.6 to 800 amu in 0.1 amu steps, and scan speed reaches 5,200 amu/s. SIM mode supports up to 50 groups of 30 masses, with dwell times of 9 to 9,999 ms per mass.

The CombiPAL is a top-mounted XYZ robot autosampler that combines liquid injection, static headspace, and SPME in one instrument. Its syringe-only design has no sample loops, transfer lines, or valves in the sample path. Liquid injection volumes reach 500 µL for large-volume injection, and sampling style can be changed within a single sequence.

This refurbished Agilent 6890A Plus GC with 5973 MSD and CTC Analytics CombiPAL Autosampler has been fully tested and verified to be in proper working condition by Alliant Scientific.

Includes:

  • Agilent 6890A Plus GC
    • 1 Split/Splitless (S/SL) Inlet
    • 1 Purged Packed Inlet
    • CO2 Coolant Valve
  • Agilent 5973 MSD
  • CTC Analytics CombiPAL Autosampler
    • Gameboy
    • XYZ Robotic Arm
    • Syringe Holder
    • Sample Tray & Tray Holder
    • Agitator
    • Power Supply
    • GC Mounting Kit
  • Data System
  • 90-Day Warranty

Looking for Other GC/MS Systems?

Browse our full GC/MS systems inventory for other configurations.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies; CTC Analytics (autosampler)
GC Model 6890A Plus
Inlets 1 split/splitless (S/SL) inlet; 1 purged packed inlet
Pneumatic Control Electronic pneumatic control (EPC), 0.001 psi resolution
Oven Temperature Range −40 °C (with CO2 cooling) to 450 °C
Oven Programming 20 ramps, 21 plateaus
Oven Cooling CO2 coolant valve
MSD Model 5973 MSD
Ionization Mode Electron ionization (EI)
Mass Range 1.6 to 800 amu, in 0.1 amu steps
Scan Speed Up to 5,200 amu/s
SIM Up to 50 groups of 30 masses; dwell 9 to 9,999 ms per mass
Dynamic Range 106
Ion Source Temperature Up to 250 °C (EI)
Quadrupole Temperature Up to 200 °C
Interface Temperature Up to 350 °C
Autosampler CTC Analytics CombiPAL, top-mounted XYZ robot with syringe-only sample path
Sampling Modes Liquid injection, static headspace, SPME
Liquid Injection Volume Up to 500 µL (large-volume injection)
Heated Headspace Syringe 30 to 150 °C; 1.0, 2.5, or 5.0 mL syringe sizes
Condition Refurbished and tested
Warranty 90 days

Additional information

Brand

Condition

Model

, ,

Onsite Installation

Warranty

Availability

Key Features

  • Two Inlets
    S/SL inlet for split and splitless injection, plus a purged packed inlet for packed and wide-bore capillary columns.
  • CO2 Oven Cooling
    A CO2 coolant valve extends the oven range below ambient, down to −40 °C.
  • Electronic Pneumatic Control
    EPC meters every gas flow and compensates for ambient temperature and pressure changes.
  • 5973 MSD
    EI single quadrupole with 1.6 to 800 amu range and scan speeds up to 5,200 amu/s.
  • SIM Acquisition
    Up to 50 groups of 30 masses for targeted, trace-level quantitation.
  • Three Sampling Modes
    The CombiPAL runs liquid, static headspace, and SPME injection from one autosampler.
  • Syringe-Only Sample Path
    No sample loops, transfer lines, or valves, which removes dead volume and adsorption effects.

Applications

  • Environmental Analysis
    Volatile and semivolatile organic compounds by liquid and headspace GC/MS.
  • Forensics and Toxicology
    Compound identification using library-searchable EI spectra.
  • Food, Flavor, and Fragrance
    Volatile aroma and flavor profiling by static headspace and SPME.
  • Pharmaceuticals and Chemicals
    Residual solvents, polymer additives, and impurity identification.
  • Sub-Ambient and Packed Column Methods
    CO2 cooling and the purged packed inlet support light-gas and packed-column work.

FAQ (Frequently Asked Questions)

What inlets does this GC have?

One split/splitless (S/SL) inlet and one purged packed inlet.

Can the oven run below ambient temperature?

Yes — the CO2 coolant valve extends the oven range down to −40 °C.

What sampling modes does the CombiPAL support?

Liquid injection (up to 500 µL), static headspace, and SPME. Available modes depend on the installed options.

Can the CombiPAL switch sampling modes during a run?

Yes — sampling style can be changed within a single sequence.

What mass range does the 5973 cover?

1.6 to 800 amu in 0.1 amu steps.

Does this system include a warranty?

Yes — this system ships with a 90-day warranty.