Agilent 7890B GC with 5977A MSD

Listing #:LS-004792
Brand:Agilent
Model:5977A (G7037A), 7890B
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$32,950.00
In Stock
Make an Offer

Agilent 7890B GC with 5977A MSD — GC-MS system with a single split/splitless inlet and a 5977A mass selective detector for volatile and semi-volatile organic analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 7890B GC with 5977A MSD Overview

The Agilent 7890B GC with 5977A MSD pairs a 7890B gas chromatograph, configured with a single split/splitless (SSL) inlet, with a 5977A mass selective detector. A single inlet and column keep the flow path simple, which suits laboratories that run one validated method at a time and want a clean, easy-to-maintain GC-MS. The 7890B supplies the electronic pneumatics control (EPC) and a fast, multi-ramp oven, and the 5977A scans from 1.6 to 1050 u at unit mass resolution. Library matching of the full-scan spectra is how most users identify unknowns.

On the mass spectrometer side, the 5977A offers scan rates up to 12,500 u/s. Its SIM mode handles up to 60 ions in each of 100 groups, so you can run full-scan screening and targeted quantitation on the same instrument. A heated monolithic quadrupole and a triple-axis detector keep mass assignment stable from run to run. A transfer line holds the column effluent at temperature between the GC oven and the ion source. This Agilent 7890B GC with 5977A MSD can be automated later by adding a 7693 injector tower and tray. If you need an autosampler from day one, see the Agilent 7890B 5977A GC/MS with 7693 autosampler.

Environmental, food and beverage, pharmaceutical, petrochemical, forensic and toxicology laboratories use GC-MS of this class for volatile and semi-volatile organic analysis and for identifying unknown peaks.

This Agilent 7890B GC with 5977A MSD is offered fully refurbished and tested, in working condition, by Alliant Scientific. It ships with a 90-day warranty, and onsite installation is available on request.

Includes:

  • Agilent 7890B (G3440B) Gas Chromatograph
    • Single Split/Splitless (SSL) Inlet
    • MSD Interface
  • Agilent 5977A Mass Selective Detector (MSD)
  • Dell PC with Data System
  • Cables and Connectors
  • 90-Day Warranty

Optional:

  • Additional Inlets & Detectors
  • Premium Refurbishment with Extended Warranty

Looking for Other GC-MS Systems?

Browse our full GC inventory for other GC and GC-MS configurations.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
GC Model 7890B (G3440B)
Mass Spectrometer 5977A Mass Selective Detector (MSD)
Inlet Single split/splitless (SSL); split ratio up to 7,500:1
Gas Control Electronic pneumatics control (EPC)
Oven Programming Up to 20 ramps and 21 plateaus
Oven Cool-Down 450 to 50 °C in about 4 minutes
Mass Range 1.6 to 1050 u
Mass Resolution Unit mass
Scan Rate Up to 12,500 u/s
SIM Capacity 60 ions x 100 groups
Mass Axis Stability Better than 0.10 u over 48 hours
Detector Triple-axis detector, triple-channel electron multiplier
Mass Filter Heated monolithic hyperbolic quadrupole
Ion Source Temperature 150 to 350 °C
Transfer Line Temperature 100 to 350 °C
Data System Included (Dell PC, Windows 11)
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Condition

Brand

Model

,

Warranty

Onsite Installation

Available upon request

Key Features

  • 5977A MSD
    Scans 1.6 to 1050 u at unit mass resolution.
  • Single SSL Inlet
    One inlet and column keep the flow path simple. Split ratios go up to 7,500:1.
  • Scan and SIM in One Method
    Run full-scan screening and targeted SIM, with up to 60 ions in each of 100 groups.
  • Up to 12,500 u/s
    Fast scanning for narrow, fast-eluting peaks.
  • Stable Mass Axis
    Drift stays under 0.10 u over 48 hours.
  • Up to 20 Oven Ramps
    Detailed temperature programs for complex mixtures.
  • 450 to 50 °C in about 4 Minutes
    Fast cool-down for more injections per day.
  • Autosampler Ready
    Add a 7693 injector tower and tray when you are ready to automate.

Applications

  • Environmental Testing
    Volatile and semi-volatile organic compounds.
  • Food and Beverage
    Flavor, aroma and contaminant screening.
  • Pharmaceutical
    Residual solvents and impurity identification.
  • Petrochemical
    Hydrocarbon and fuel composition.
  • Forensics and Toxicology
    Screening and confirmation by library match.
  • Unknown Identification
    Match full-scan spectra against a spectral library.

FAQ (Frequently Asked Questions)

What does this system include?

An Agilent 7890B GC with one SSL inlet, a 5977A MSD and a data system.

Does it include an autosampler?

No. A 7693 injector tower (G4513A) and tray (G4514A) are available separately.

Can I add a second inlet?

Yes. Additional inlets are available on request.

What is the mass range?

1.6 to 1050 u.

Can it run SIM?

Yes, with up to 60 ions in each of 100 groups.

Does this system include a warranty?

Yes. It ships with a 90-day warranty.