Lease/Rent

Agilent 5975T LTM GC/MSD with 7683 Autosampler

Listing #:LS-007621
Brand:
Model:5975T, G2913A, G4362A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$16,100.00
In Stock
Make an Offer

Agilent 5975T LTM GC/MSD with 7683 Autosampler — compact, transportable GC-MS with LTM column heating, an EI quadrupole MSD and a 7683 G2913A injector for automated GC/MS identification at a lower cost. Refurbished and tested by Alliant Scientific.

Description

5975T LTM GC/MSD with 7683 Autosampler Overview

This Agilent 5975T LTM GC/MSD with 7683 Autosampler combines a space-saving, transportable GC-MS with Agilent’s long-established 7683 liquid injector. The 7683 has been a standard GC autosampler in labs for years, so syringes, vials and turret parts are easy to find and staff often already know how to run it. Paired with the 5975T, it makes automated GC-MS identification affordable for labs that want unattended injections without paying for the newest sampler. The low thermal mass (LTM) column module heats and cools rapidly, so short methods run back to back with little waiting between samples.

Inside the 5975T with 7683

The G2913A injector holds up to eight 2 mL sample vials in its turret, plus two wash solvents that rinse the syringe between injections to prevent carryover. It injects a set fraction of the syringe volume into the split/splitless inlet, and can repeat injections from the same vial when replicates are needed. Inside the GC, the column sits in the LTM module, wrapped with its own heater and temperature sensor instead of a large air-bath oven, which keeps temperature programs fast and power use low. Separated compounds pass to the mass selective detector, where electron ionization produces fragment spectra that the data system compares against reference libraries for identification.

This Agilent 5975T LTM GC/MSD with 7683 Autosampler is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Agilent 5975T LTM GC/MSD
    • 7683B Series G2913A Autosampler
    • PC with data system
  • 90-day warranty

See Other configurations: the Agilent 5975T LTM GC/MSD System and the Agilent 5975T LTM GC/MSD with 7693 Autosampler

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

5975T LTM GC/MSD with 7683 Autosampler Specifications

Manufacturer Agilent
Model 5975T LTM GC/MSD with 7683 Autosampler
Condition Refurbished
Column Heating LTM module, up to 1200 °C/min ramp
Inlet Split/splitless
Ion Source Inert EI source, up to 350 °C
Mass Analyzer Quadrupole MSD
Mass Range 1.8–1050 u
Autosampler Agilent 7683, G2913A injector
Turret Capacity 8 x 2 mL sample vials
Wash Solvents 2 (Solvent A and Solvent B)
Syringe Sizes 0.5 to 100 µL
Injection Volume 0.1 to 50 µL
Injections per Vial 1 to 99
Data System PC with data system included
Warranty 90 days

Additional information

Availability

Brand

Model

, ,

Condition

Onsite Installation

Warranty

5975T LTM GC/MSD with 7683 Autosampler Key Features

  • 8-vial turret: automated injection of a full small batch without an operator.
  • 2 wash solvents: syringe rinsing between samples to limit carryover.
  • 0.1–50 µL injections: syringes from 0.5 to 100 µL for trace or concentrated samples.
  • 1–99 injections per vial: built-in replicate injections for precision checks.
  • Proven 7683 platform: widely used sampler with easy-to-source syringes and parts.
  • LTM column module: rapid heating and cooling for short cycle times.
  • EI quadrupole MSD: library-searchable spectra across 1.8–1050 u.
  • Transportable design: compact GC-MS that fits small labs and mobile setups.

5975T LTM GC/MSD with 7683 Autosampler Applications

  • Pesticide residue labs: GC/MS screening of fruit, vegetable and grain extracts for pesticide residues.
  • Toxicology labs: screening biological sample extracts for drugs, poisons and their metabolites.
  • Petroleum and fuel labs: hydrocarbon profiling and checking fuels and oils for contamination.
  • Polymer and materials labs: identifying plasticizers, additives and extractables from plastics and packaging.
  • Natural products researchers: identifying volatile and semivolatile compounds in plant extracts.
  • Labs on a tighter budget: adding automated GC/MS identification at a lower cost than newer autosampler setups.

5975T LTM GC/MSD with 7683 Autosampler FAQ

Which injector is included with this 5975T?
The Agilent 7683 G2913A injector.

How many vials fit in the turret?
Eight 2 mL sample vials.

What syringe sizes can it use?
0.5 µL to 100 µL.

Can it make replicate injections?
Yes, 1 to 99 injections from the same vial.

What is the difference between this and the 7693 version?
The 7693 G4513A has a 16-position turret; the 7683 G2913A holds 8 sample vials.

Is a data system included?
Yes. A PC with data system is included.

What warranty is included?
A 90-day warranty.