Agilent 7890B 5977B GC/MS with 7693 Autosampler — single-quadrupole GC-MS system with an EI source, turbomolecular pump and automatic liquid sampler for environmental, food, pharmaceutical and forensic analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 7890B 5977B GC/MS Overview

The Agilent 7890B 5977B GC/MS is a single-quadrupole system that couples a 7890B gas chromatograph, configured with one split/splitless (S/SL) inlet, to a 5977B mass selective detector with an electron ionization (EI) source. The 5977B scans from 1.6 to 1050 u and holds its mass axis to within 0.10 u over 48 hours, so library spectra and calibrations stay consistent from batch to batch. A turbomolecular pump brings the analyzer to vacuum, and the 7890B oven programs multiple ramps and cools quickly between runs. Full-scan data supports spectral library searching, and SIM mode is available for targeted quantitation at lower levels.

This Agilent 7890B 5977B GC/MS ships with a 7693 Series automatic liquid sampler, so sequences run unattended once the vials are loaded. The G4513A injector tower and G4514A sample tray handle the injections, and the 7890B’s electronic pneumatics control (EPC) keeps flows and pressures repeatable between samples. The GC supports split, splitless, pulsed split and pulsed splitless injection, which covers both trace work and more concentrated samples.

For a configuration built around the earlier detector, see the Agilent 7890B 5977A GC/MS.

Environmental laboratories running volatile organic compound (VOC) methods, food and beverage testing labs, pharmaceutical and chemical analysts, and forensic and toxicology laboratories use GC-MS systems like the Agilent 7890B 5977B GC/MS for screening, identification and quantitation.

The system is offered fully refurbished and tested, in working condition, by Alliant Scientific. It ships with a 90-day warranty, and onsite installation is available on request.

Includes:

  • Agilent 7890B (G3440B) Gas Chromatograph
    • Single Split/Splitless (S/SL) Inlet
    • MSD Interface
  • Agilent 5977B Mass Selective Detector (G7080B)
    • Electron Ionization (EI) Source
  • Agilent 7693 Series Autosampler
    • Injector Tower (G4513A)
    • Sample Tray (G4514A)
  • Data System
  • 90-Day Warranty

Optional:

  • Premium Refurbishment with Extended Warranty

Looking for Other GC-MS Systems?

Browse our full GC-MS inventory for other GC-MS configurations.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
GC Model 7890B (G3440B)
Mass Spectrometer 5977B Mass Selective Detector (G7080B), single quadrupole
Ionization Electron ionization (EI)
Inlet Single split/splitless (S/SL)
Injection Modes Split, splitless, pulsed split, pulsed splitless
Gas Control Electronic pneumatics control (EPC)
Mass Range 1.6 to 1050 u
Acquisition Modes Full scan and SIM
Mass Axis Stability Better than 0.10 u over 48 hours
Detector Triple-axis detector
Ion Source Temperature 150 to 350 °C
Quadrupole Temperature 106 to 200 °C
Vacuum Pump Turbomolecular
Autosampler Agilent 7693 Series with G4513A tower and G4514A tray
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Condition

Brand

Model

, , ,

Onsite Installation

Warranty

Key Features

  • 5977B MSD
    Single quadrupole with an EI source and a 1.6 to 1050 u mass range.
  • Mass Axis Stable to 0.10 u over 48 Hours
    Consistent spectra for library matching.
  • Scan and SIM Modes
    Full-scan identification and targeted quantitation on one system.
  • Triple-Axis Detector
    Reduces neutral noise reaching the detector.
  • 7693 Autosampler
    G4513A tower and G4514A tray for unattended sequences.
  • Four Injection Modes
    Split, splitless, pulsed split and pulsed splitless.
  • Turbomolecular Pumping
    Fast pump-down for the analyzer.
  • EPC Gas Control
    Repeatable retention times and flows.

Applications

  • Environmental and VOC Analysis
    Volatile and semi-volatile organic compounds.
  • Food and Beverage Testing
    Flavor, aroma and contaminant screening.
  • Pharmaceutical and Chemical Analysis
    Residual solvents and impurity identification.
  • Forensics and Toxicology
    Screening and confirmation by library match.
  • Quality Control
    Routine GC-MS workflows in production laboratories.

FAQ (Frequently Asked Questions)

What does this system include?

An Agilent 7890B GC, a 5977B MSD, a 7693 autosampler and a data system PC.

What is the mass range?

1.6 to 1050 u.

Does it include an autosampler?

Yes. It includes a 7693 Series with a G4513A tower and G4514A tray.

Which ionization mode does it use?

Electron ionization (EI).

Can it run SIM?

Yes. It runs full scan and SIM.

Does this system include a warranty?

Yes. It ships with a 90-day warranty.