Agilent 6890N GC with 5973 Inert MSD, OI Eclipse 4660 Purge & Trap, and Varian Archon Autosampler

Listing #:LS-005556
Model:5973, 6890N, Archon, Eclipse 4660
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
In Stock

Agilent 6890N GC with 5973 Inert MSD, OI Eclipse 4660 Purge & Trap, and Varian Archon Autosampler — purge-and-trap GC/MS system for finding volatile organic compounds in water, with an automatic sample loader. Refurbished and tested by Alliant Scientific.

Description

Agilent 6890N GC with 5973 Inert MSD Overview

Agilent 6890N GC with 5973 Inert MSD is built into a purge-and-trap system for finding volatile organic compounds (VOCs) in water. The OI Analytical Eclipse 4660 concentrator bubbles gas through each sample to strip the volatile compounds out and collects them on a trap. It then heats the trap to release them onto the 6890N gas chromatograph, and the 5973 Inert MSD identifies each compound by its mass spectrum. A Varian Archon autosampler loads the samples one after another, so a long water-testing sequence can run without anyone standing at the instrument.

Purge and trap is what makes this setup different from a standard GC/MS, because it can reach volatile compounds that a direct liquid injection would not. The 5973 has an inert ion source and can scan all masses or watch selected ions. Drinking water, wastewater and groundwater laboratories use the Agilent 6890N GC with 5973 Inert MSD for VOC screening and measurement, and municipal and contract testing laboratories use it as a dedicated VOC workstation.

This Agilent 6890N GC with 5973 Inert MSD, OI Eclipse 4660 Purge & Trap, and Varian Archon Autosampler is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Agilent 6890N GC/MS purge-and-trap system
    • Agilent 6890N GC (G1530N)
      • Split/Splitless (SSL) Inlet
    • Agilent 5973 Inert MSD
    • OI Analytical Eclipse 4660 Purge and Trap Sample Concentrator
    • Varian Archon Purge and Trap Autosampler
    • Vacuum Pump
  • Dell PC with Windows 11 Pro and Data System
  • 90 Day Warranty

Looking for Other GC/MS Systems?

Browse our full GC/MS inventory.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies, OI Analytical, Varian
System Type Purge-and-trap GC/MS system
Gas Chromatograph 6890N (G1530N)
Inlet Single split/splitless (SSL), electronic pneumatic control
Columns Capillary
Mass Spectrometer 5973 Inert MSD, quadrupole analyzer
Ion Source Electron ionization (EI), inert source
Acquisition Modes Full scan and selected ion monitoring (SIM)
Concentrator OI Analytical Eclipse 4660 purge and trap
Concentrator Features Heated sparge vessel, moisture control, trap cooling
Autosampler Varian Archon purge-and-trap autosampler
Computer Dell PC with Windows 11 Pro and data system
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Condition

Brand

, ,

Model

, , ,

Onsite Installation

Warranty

Key Features

  • Purge-and-Trap Front End
    Eclipse 4660 concentrator strips VOCs from water onto a trap.
  • Varian Archon Autosampler
    Loads samples automatically, one after another.
  • 6890N GC with SSL Inlet
    Electronic pneumatic control, capillary columns.
  • 5973 Inert MSD
    Quadrupole mass spectrometer with an inert EI source.
  • Full Scan and SIM
    Scan all masses or watch selected ions.
  • Moisture Control and Trap Cooling
    Built into the Eclipse 4660 concentrator.
  • Heated Sparge Vessel
    Warms the sample during purging.
  • PC Included
    Dell PC with Windows 11 Pro and data system.

Applications

  • Drinking Water VOCs – Water utilities and certified drinking water laboratories measure regulated volatile organic compounds, such as benzene, vinyl chloride and trihalomethanes, by purge and trap GC/MS under EPA Method 524.2.
  • Wastewater VOCs – Municipal and industrial wastewater laboratories test discharge and permit samples for volatile pollutants under EPA Method 624.
  • Groundwater and Hazardous Waste Sites – Environmental contract laboratories analyze groundwater, leachate and soil samples for VOCs under EPA SW-846 Method 8260 for site investigation and remediation monitoring.
  • Dedicated VOC Workstation – Municipal and contract laboratories run this system as a dedicated, automated VOC line for routine batches of water samples.

Frequently Asked Questions

What is included in the Agilent 6890N GC with 5973 Inert MSD system?

A 6890N GC with one SSL inlet, a 5973 Inert MSD, an OI Eclipse 4660 purge and trap concentrator, a Varian Archon autosampler, a vacuum pump and a data system.

What is purge and trap used for?

It strips volatile organic compounds out of a water sample, collects them on a trap and releases them onto the GC.

What type of mass spectrometer does it have?

A 5973 Inert MSD with an electron ionization source and a quadrupole analyzer.

Does it run full scan and SIM?

Yes. It supports full scan and selected ion monitoring.

Does the autosampler load samples automatically?

Yes. The Varian Archon loads samples one after another.

Does it include a computer?

Yes. A Dell PC with Windows 11 Pro and a data system.

What warranty does it have?

The system is refurbished and tested, and it ships with a 90-day warranty.