Description
Agilent 7890A GC with G1888 Headspace Sampler Overview
The Agilent 7890A Gas Chromatograph (GC) paired with the G1888 Headspace Autosampler, configured with a single Flame Ionization Detector (FID) and Split/Splitless (SSL) inlet, is a robust and highly reliable solution for the analysis of volatile compounds in complex sample matrices. This system is specifically designed for headspace gas chromatography applications, enabling accurate and reproducible measurement of volatile organic compounds (VOCs) without direct sample injection. The G1888 Headspace Sampler automates vial pressurization, equilibration, and sample transfer, reducing contamination risk while improving repeatability and throughput.
The 7890A GC platform provides stable temperature control, precise Electronic Pneumatic Control (EPC), and consistent chromatographic performance. The integrated FID detector delivers high sensitivity for hydrocarbons, offering a wide dynamic range ideal for trace-level and high-concentration analysis. This configuration is widely used in industries such as pharmaceuticals, environmental testing, food and beverage, and forensic analysis, where reliable headspace sampling is essential for volatile compound detection.
Agilent 7890A GC with G1888 Headspace Sampler is offered fully refurbished and tested, in working condition.
 Includes:
- Agilent 7890A Gas Chromatograph (GC)
- Single Split/Splitless Inlet (SSL)
- Single Flame Ionization Detector (FID)
- Agilent G1888 Headspace Sampler
- Data System
- 90- Day Warranty Coverage
Disclaimer:Â All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.
Technical Specifications
| General | |
|---|---|
| Instrument Type | Gas Chromatograph with Headspace Sampler |
| Model | Agilent 7890A GC |
| Configuration | Single FID, Single SSL Inlet with G1888 Headspace Sampler |
| Headspace System | Agilent G1888 Headspace Autosampler |
| Application Range | Volatile organic compound (VOC) analysis via headspace sampling |
| Headspace Sampler (G1888) | |
| Sampling Method | Static headspace sampling |
| Vial Handling | Automated pressurization and injection |
| Temperature Control | Independent vial oven and transfer line heating |
| Injection Type | Loop-based sample transfer to GC inlet |
| Automation | High-throughput multi-vial processing |
| Inlet System | |
| Inlet Type | Split / Splitless (SSL) |
| Configuration | Single inlet |
| Temperature Range | Up to ~400°C (configuration dependent) |
| Control | Electronic Pneumatic Control (EPC) |
| Oven | |
| Temperature Range | Ambient +4°C to ~450°C |
| Ramp Programming | Multi-step programmable temperature gradients |
| Cooling | Forced-air cooling |
| Detector (FID) | |
| Type | Flame Ionization Detector (FID) |
| Detection Principle | Ionization of organic compounds in hydrogen-air flame |
| Sensitivity | High sensitivity to hydrocarbons (pg carbon level) |
| Dynamic Range | ~10^7 linear range |
| Ignition | Electronic ignition |
| Required Gases | Hydrogen, Air, Makeup gas (Nitrogen or Helium) |
| Pneumatics | |
| Control System | Electronic pressure and flow control (EPC) |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| System Integration | |
| Software | Agilent ChemStation / OpenLab CDS |
| Interfaces | LAN / standard instrument communication protocols |
| Physical | |
| Form Factor | Bench-top GC with headspace module |
| Footprint | GC system with integrated headspace autosampler |
| Build | Designed for continuous analytical laboratory operation |
``
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
- Agilent 7890A GC with proven reliability and high-performance separation
- G1888 Headspace Autosampler for automated volatile compound analysis
- Single Split/Splitless (SSL) inlet for flexible injection methods
- Flame Ionization Detector (FID) for high-sensitivity hydrocarbon detection
- Automated vial pressurization and sample transfer for consistent results
- Reduces matrix interference by analyzing headspace vapor only
- Wide linear dynamic range (~10^7) for quantitative accuracy
- Electronic Pneumatic Control (EPC) for precise gas flow regulation
- Improved reproducibility and reduced operator variability
- Compatible with Agilent ChemStation and OpenLab CDS software
Applications
- Residual solvent analysis in pharmaceuticals
- Environmental VOC analysis in soil and water
- Food and beverage aroma and contaminant testing
- Forensic toxicology and alcohol analysis
- Polymer and packaging off-gassing analysis
- Chemical quality control and process monitoring
Frequently Asked Questions (FAQ)
What is the benefit of using a headspace sampler?
Headspace sampling isolates volatile compounds from complex matrices, reducing contamination and improving analytical reproducibility.
What types of samples can be analyzed?
This system is ideal for liquids and solids that release volatile compounds, including pharmaceuticals, food products, and environmental samples.
How does the G1888 headspace system improve accuracy?
It automates vial equilibration, pressurization, and injection, minimizing variability and ensuring consistent sample introduction.
What detector is used in this system?
The system uses a Flame Ionization Detector (FID), providing high sensitivity for hydrocarbon and organic compound analysis.
Is this system suitable for regulated environments?
Yes, it integrates with Agilent ChemStation and OpenLab CDS, supporting compliance-ready workflows.








