Lease/Rent

Agilent 7890A GC with G1888 Headspace Sampler

Listing #:LS-005754
Brand:Agilent
Model:7890A (G3440A), G1888
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
In Stock

Description

Agilent 7890A GC with G1888 Headspace Sampler Overview

The Agilent 7890A Gas Chromatograph (GC) paired with the G1888 Headspace Autosampler, configured with a single Flame Ionization Detector (FID) and Split/Splitless (SSL) inlet, is a robust and highly reliable solution for the analysis of volatile compounds in complex sample matrices. This system is specifically designed for headspace gas chromatography applications, enabling accurate and reproducible measurement of volatile organic compounds (VOCs) without direct sample injection. The G1888 Headspace Sampler automates vial pressurization, equilibration, and sample transfer, reducing contamination risk while improving repeatability and throughput.

The 7890A GC platform provides stable temperature control, precise Electronic Pneumatic Control (EPC), and consistent chromatographic performance. The integrated FID detector delivers high sensitivity for hydrocarbons, offering a wide dynamic range ideal for trace-level and high-concentration analysis. This configuration is widely used in industries such as pharmaceuticals, environmental testing, food and beverage, and forensic analysis, where reliable headspace sampling is essential for volatile compound detection.

Agilent 7890A GC with G1888 Headspace Sampler is offered fully refurbished and tested, in working condition.

 Includes:

  • Agilent 7890A Gas Chromatograph (GC)
    • Single Split/Splitless Inlet (SSL)
    • Single Flame Ionization Detector (FID)
  • Agilent G1888 Headspace Sampler
  • Data System
  • 90- Day Warranty Coverage

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Technical Specifications

General
Instrument Type Gas Chromatograph with Headspace Sampler
Model Agilent 7890A GC
Configuration Single FID, Single SSL Inlet with G1888 Headspace Sampler
Headspace System Agilent G1888 Headspace Autosampler
Application Range Volatile organic compound (VOC) analysis via headspace sampling
Headspace Sampler (G1888)
Sampling Method Static headspace sampling
Vial Handling Automated pressurization and injection
Temperature Control Independent vial oven and transfer line heating
Injection Type Loop-based sample transfer to GC inlet
Automation High-throughput multi-vial processing
Inlet System
Inlet Type Split / Splitless (SSL)
Configuration Single inlet
Temperature Range Up to ~400°C (configuration dependent)
Control Electronic Pneumatic Control (EPC)
Oven
Temperature Range Ambient +4°C to ~450°C
Ramp Programming Multi-step programmable temperature gradients
Cooling Forced-air cooling
Detector (FID)
Type Flame Ionization Detector (FID)
Detection Principle Ionization of organic compounds in hydrogen-air flame
Sensitivity High sensitivity to hydrocarbons (pg carbon level)
Dynamic Range ~10^7 linear range
Ignition Electronic ignition
Required Gases Hydrogen, Air, Makeup gas (Nitrogen or Helium)
Pneumatics
Control System Electronic pressure and flow control (EPC)
Carrier Gas Options Helium, Hydrogen, Nitrogen
System Integration
Software Agilent ChemStation / OpenLab CDS
Interfaces LAN / standard instrument communication protocols
Physical
Form Factor Bench-top GC with headspace module
Footprint GC system with integrated headspace autosampler
Build Designed for continuous analytical laboratory operation

``

Additional information

Availability

Brand

Condition

Model

,

Onsite Installation

Warranty

Key Features

  • Agilent 7890A GC with proven reliability and high-performance separation
  • G1888 Headspace Autosampler for automated volatile compound analysis
  • Single Split/Splitless (SSL) inlet for flexible injection methods
  • Flame Ionization Detector (FID) for high-sensitivity hydrocarbon detection
  • Automated vial pressurization and sample transfer for consistent results
  • Reduces matrix interference by analyzing headspace vapor only
  • Wide linear dynamic range (~10^7) for quantitative accuracy
  • Electronic Pneumatic Control (EPC) for precise gas flow regulation
  • Improved reproducibility and reduced operator variability
  • Compatible with Agilent ChemStation and OpenLab CDS software

Applications

  • Residual solvent analysis in pharmaceuticals
  • Environmental VOC analysis in soil and water
  • Food and beverage aroma and contaminant testing
  • Forensic toxicology and alcohol analysis
  • Polymer and packaging off-gassing analysis
  • Chemical quality control and process monitoring

Frequently Asked Questions (FAQ)

What is the benefit of using a headspace sampler?

Headspace sampling isolates volatile compounds from complex matrices, reducing contamination and improving analytical reproducibility.

What types of samples can be analyzed?

This system is ideal for liquids and solids that release volatile compounds, including pharmaceuticals, food products, and environmental samples.

How does the G1888 headspace system improve accuracy?

It automates vial equilibration, pressurization, and injection, minimizing variability and ensuring consistent sample introduction.

What detector is used in this system?

The system uses a Flame Ionization Detector (FID), providing high sensitivity for hydrocarbon and organic compound analysis.

Is this system suitable for regulated environments?

Yes, it integrates with Agilent ChemStation and OpenLab CDS, supporting compliance-ready workflows.