Agilent 7890B 5977A 7697A GC-MS Overview

The Agilent 7890B 5977A 7697A GC-MS system combines three instruments that each remove a different source of variability. The 7697A headspace sampler heats a sealed vial and injects only the vapor, so non-volatile matrix never reaches the inlet or column. Before each run it checks the vial seal automatically, and it controls vial pressure and column head pressure independently, which keeps injections consistent from vial to vial. Samples can be extracted once, or repeatedly from the same vial in multiple headspace extraction mode, which is how you quantify volatiles in solids and polymers where the compound doesn’t release in one step. The sample path is deactivated stainless steel, which helps with active compounds.

The 7890B GC separates what the sampler delivers. Electronic pneumatics control holds gas flow and pressure steady for repeatable retention times, and the multi-ramp oven can be programmed for complex boiling-point ranges. The 5977A VL inert MSD then detects the separated compounds with electron ionization, producing standard spectra for library matching. Its quadrupole is independently heated, and a one-click autotune handles the standard BFB and DFTPP tune checks used in regulated environmental methods. Acquisition runs in full scan, SIM or synchronous SIM/scan, with automated SIM setup.

Pharmaceutical, environmental, food and beverage, forensic and toxicology, and chemical laboratories use the Agilent 7890B 5977A 7697A GC-MS for residual solvents, volatile organic compounds, flavor and aroma profiling, and blood alcohol and accelerant testing. The 7693 autosampler on the same system handles liquid injections for semi-volatile work.

This 7890B GC with 5977A MSD, 7697A Headspace and 7963 Autosampler is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 7890B (G3440B) Gas Chromatograph
    • Split/Splitless (SSL) Inlet
  • Agilent 5977A VL Inert Mass Selective Detector (G7037A)
  • Agilent G7697A Headspace Sampler
  • Agilent 7693 Series Autosampler
    • G4513A Injector Tower
    • G4514A Vial Tray
  • Dell PC with Data System
  • Vacuum Pump
  • 90-Day Warranty

Optional:

  • Premium Refurbishment with Extended Warranty

Looking for Other GC-MS Systems?

Browse our full GC-MS inventory for other GC/MS, GC-MS/MS and GC-Q-TOF systems.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 7890B GC (G3440B) with 5977A VL Inert MSD (G7037A), 7697A headspace sampler and 7693 autosampler
Mass Analyzer Single quadrupole
Mass Range 1.6–1,050 u
Ionization Electron ionization (EI), inert source
EI Source Temperature 150–350 °C
Quadrupole Temperature 106–200 °C
Acquisition Modes Full scan, SIM, synchronous SIM/scan
GC Oven Ambient +4 to 450 °C; up to 20 ramps and 21 plateaus
GC Inlet Split/splitless (SSL); split ratio up to 7,500:1
Gas Control Electronic pneumatics control (EPC)
Headspace Sampler 7697A static headspace; 10, 20 and 22 mL vials; 1 mL standard loop
Headspace Modes Single extraction, multiple headspace extraction (up to 100 per vial), multiple headspace collection
Liquid Autosampler 7693 Series; G4513A tower and G4514A tray; 150 vials in three 5 x 10 racks
Vacuum System Vacuum pump included
Data System Dell PC, Windows 11 Pro
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

, , , ,

Onsite Installation

Warranty

Key Features

  • Static Headspace, 7697A
    Inject only the vapor, which keeps non-volatile matrix out of the inlet and column.
  • Automatic Vial Leak Check
    Confirms every vial is sealed before sampling.
  • Independent Vial and Column Pressure Control
    Vial pressurization and GC column head pressure are set separately for repeatable transfers.
  • Multiple Headspace Extraction, up to 100
    Repeat the extraction on one vial for matrices where volatiles release slowly.
  • Deactivated Stainless Steel Flow Path
    An inert sample path for active compounds.
  • Inert EI Source with Heated Quadrupole
    Reproducible spectra for active and trace compounds, matched to standard EI libraries.
  • One-Click Autotune for BFB and DFTPP
    Tune checks used in regulated environmental methods.
  • Full Scan, SIM and Synchronous SIM/Scan
    Identify unknowns and measure targets in the same run, with automated SIM setup.
  • EPC Gas Control on the 7890B
    Repeatable retention times and peak areas.
  • Headspace and Liquid Injection
    The 7693 autosampler runs liquid samples on the same GC/MS.

Applications

  • Residual Solvents
    Pharmaceutical products and raw materials, including USP residual solvent methods.
  • Environmental Analysis
    Volatile organic compounds in water, soil and air extracts.
  • Food and Beverage Testing
    Flavor and aroma compounds, contaminants and packaging migration.
  • Forensics and Toxicology
    Blood alcohol, accelerants and solvent screening.
  • Chemical and Industrial Quality Control
    Trace impurities, process monitoring and batch consistency.

FAQ (Frequently Asked Questions)

What does this system include?

An Agilent 7890B GC with an SSL inlet, a 5977A VL inert MSD, a 7697A headspace sampler, a 7693 autosampler with tower and tray, a vacuum pump and a data system.

What does the headspace sampler do?

It heats a sealed vial and injects only the vapor above the sample onto the column.

What headspace modes are available?

Single extraction, multiple headspace extraction and multiple headspace collection.

What is the mass range?

1.6 to 1,050 u.

Can it also run liquid injections?

Yes. The 7693 autosampler handles liquid injections on the same system.

Does this system include a warranty?

Yes. It ships with a 90-day warranty.