Agilent 7890B GC with FID, TCD & S/SL Inlets — two Split/Splitless inlets paired with FID and TCD detectors for combined organic and permanent gas analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 7890B GC with FID, TCD & S/SL Inlets Overview

The Agilent 7890B GC is configured with a Flame Ionization Detector (FID), a Thermal Conductivity Detector (TCD), and two Split/Splitless (S/SL) inlets. Each inlet and detector has its own electronic pneumatic control, so gas flows and pressures are set and held independently.

The FID provides a linear dynamic range of 10^7, suited to hydrocarbons and general organic compound analysis. The TCD has a single filament, so there is no separate reference gas line to set up and no manual balance adjustment.

Capillary Flow Technology fittings make leak-free connections inside the oven, which allows heart-cutting with a Deans switch. Backflush vents heavy matrix before it reaches the detector, protecting the flow path and reducing carryover between runs.Turn-Top inlet seals let you change liners without tools, and the inert sample path helps active compounds such as acids and amines reach the detector instead of sticking along the way.

Petrochemical, environmental and food safety laboratories use the Agilent 7890B GC with FID, TCD and S/SL inlets, and so do laboratories that analyze gases. This unit is offered fully refurbished and tested, in working condition, by Alliant Scientific. It ships with a 90-day warranty, and onsite installation is available on request.

This Agilent 7890B GC with FID, TCD & S/SL Inlets is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 7890B Gas Chromatograph (G3440B)
    • Flame Ionization Detector (FID)
    • Thermal Conductivity Detector (TCD)
    • Two Split/Splitless (S/SL) Inlets
  • Data System
  • 90-Day Warranty

Browse our full Gas Chromatography inventory for other options.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 7890B (G3440B)
Detectors FID, TCD
Inlets Two Split/Splitless (S/SL)
Pneumatics Control Electronic Pneumatic Control (EPC), all inlets/detectors
Pressure Metering Precision 0.001 psi
Flow Metering Precision 0.05 mL/min
FID Linear Dynamic Range 10^7
TCD Design Single-filament
TCD Data Acquisition Rate Up to 200 Hz
Oven Temperature Range Ambient +4°C to 450°C
Inlet Sealing System Turn-Top, tool-free liner changes
Flow Path Inert Flow Path design
Capillary Flow Technology Supports Deans-switch, 2D GC, backflush (no cryogen required)
Ambient Operating Humidity 5% to 95%, noncondensing
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

Onsite Installation

Warranty

Key Features

  • Dual Inlet, Dual Detector Configuration
    Two Split/Splitless inlets paired with FID and TCD detectors for broad compound coverage in one system.
  • Single-Filament TCD
    Eliminates the separate reference gas and manual potentiometer adjustment required by older dual-filament designs.
  • Backflush Without Cryogen
    Capillary Flow Technology enables in-oven backflush, venting heavy matrix before it reaches the detector.
  • Tool-Free Inlet Maintenance
    Turn-Top sealing system on both inlets allows quick liner changes.
  • Precise Gas Metering
    EPC meters carrier and detector gases to 0.001 psi and 0.05 mL/min.

Applications

  • Petrochemical Analysis
    Simultaneous detection of hydrocarbons and permanent gases in one run.
  • Environmental Testing
    Combined organic compound and fixed gas analysis for environmental samples.
  • Food Safety Testing
    Dual-detector capability supports a range of food-safety method requirements.
  • Gas Analysis
    TCD detection of permanent gases alongside FID detection of organic compounds.

FAQ (Frequently Asked Questions)

What does the TCD detect that the FID doesn’t?

TCD detects fixed/permanent gases and compounds that don’t ionize in a flame, such as carbon dioxide, nitrogen, and other inorganic gases — compounds the FID can’t detect.

Why does this system have two inlets?

Two inlets allow independent sample introduction for different methods or detectors, supporting more flexible, simultaneous analysis workflows.

What is Capillary Flow Technology used for?

It enables leak-free, in-oven connections for Deans-switch heart-cutting, two-dimensional GC, and backflush — all without requiring cryogen.

How precise is the gas flow control?

EPC meters carrier and detector gases to 0.001 psi and 0.05 mL/min, compensating for changes in ambient pressure and temperature.

Does this unit include a warranty?

Yes — this unit ships with a 90-day warranty.