Lease/Rent

Agilent 6890N GC with 7694 Headspace Sampler

Listing #:LS-006944
Brand:Agilent
Model:6890N, 7694
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$6,900.00
In Stock
Make an Offer

Agilent 6890N GC with 7694 Headspace Sampler — 6890N GC with S/SL inlet, FID, and a 44-vial automated headspace sampler for volatile analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 6890N GC with 7694 Headspace Sampler Overview

This system pairs an Agilent 6890N gas chromatograph with an Agilent 7694 Headspace Sampler for automated analysis of volatile compounds in liquid and solid samples. The GC is configured with one split/splitless (S/SL) inlet.

The 7694 Headspace Sampler runs up to 44 samples in sequence without operator attention. Its vial oven holds six 10 mL or 20 mL vials and heats from 40 to 200 °C. The valve and loop zone is set from 50 to 200 °C, and sample moves to the GC through a heated transfer line. Up to four methods can be stored on the sampler.

Headspace sampling introduces only the vapor above the sample, which keeps non-volatile matrix out of the inlet and column. This configuration suits residual solvent, blood alcohol, and volatile organic analysis.

This refurbished Agilent 6890N GC with 7694 Headspace Sampler has been fully tested and verified to be in proper working condition by Alliant Scientific.

Includes:

  • Agilent 6890N GC (G1530N)
    • 1 Split/Splitless (S/SL) Inlet
    • 1 Flame Ionization Detector (FID)
  • Agilent 7694 Headspace Sampler (G1290A)
    • 44-Vial Sample Tray
    • Sample Transfer Line
  • Data System
  • 90-Day Warranty

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Looking for Other GC Systems?

Browse our full GC inventory for other configurations.

Listing last updated: October 2026.

Technical Specifications

Manufacturer Agilent Technologies
GC Model 6890N Network GC (G1530N)
Inlet 1 split/splitless (S/SL) inlet
Inlet Maximum Temperature 450 °C
Total Flow Setting Range 0 to 200 mL/min N2; 0 to 1,000 mL/min H2 or He
Detector 1 flame ionization detector (FID)
FID Gas Control EPC for air (0 to 800 mL/min), H2 (0 to 100 mL/min), and makeup gas, N2 or He (0 to 100 mL/min)
FID Flame Control Flame-out detection with automatic reignition
Data Rate Up to 200 Hz (peaks as narrow as 25 ms at half height)
Pneumatic Control Electronic pneumatic control (EPC), 0.001 psi resolution
Oven Temperature Range Ambient +4 °C to 450 °C
Oven Programming 20 ramps, 21 plateaus
Retention Time Repeatability < 0.008% or < 0.0008 min
Headspace Sampler Model 7694 Headspace Sampler (G1290A)
Sample Tray Capacity 44 vials
Vial Oven Capacity 6 vials (10 mL or 20 mL)
Vial Oven Temperature Range 40 to 200 °C
Valve and Loop Temperature Range 50 to 200 °C
Stored Methods Up to 4
Sample Transfer Heated transfer line to GC inlet
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Onsite Installation

Warranty

Model

,

Key Features

  • Flame Ionization Detector
    Responds to hydrocarbons and other organic compounds, with flame-out detection and automatic reignition.
  • Automated Headspace Sampling
    The 7694 runs up to 44 vials in sequence without operator attention.
  • Heated Vial Oven
    Heats six 10 mL or 20 mL vials from 40 to 200 °C for thermal equilibration.
  • Heated Loop and Transfer Line
    Loop zone is set from 50 to 200 °C, and sample moves to the inlet through a heated transfer line.
  • Stored Methods
    The sampler stores up to four methods for repeat analyses.
  • Electronic Pneumatic Control
    EPC meters carrier and detector gases for repeatable retention times.
  • Wide Oven Range
    Programs up to 450 °C with 20 ramps and 21 plateaus.

Applications

  • Residual Solvent Analysis
    Volatile solvents in pharmaceutical and polymer samples.
  • Blood Alcohol Analysis
    Forensic and clinical ethanol determination by headspace GC-FID.
  • Volatile Organic Compounds
    Environmental screening of VOCs in water and soil samples.
  • Food, Beverage, and Fragrance Testing
    Volatile aroma and flavor compounds from solid and liquid matrices.

FAQ (Frequently Asked Questions)

What detector does this system have?

One flame ionization detector (FID).

How many inlets does this GC have?

One split/splitless (S/SL) inlet.

How many samples can the 7694 run unattended?

The sample tray holds 44 vials, and the vial oven holds six 10 mL or 20 mL vials at a time.

What temperature ranges does the headspace sampler cover?

The vial oven heats from 40 to 200 °C, and the valve and loop zone is set from 50 to 200 °C.

How is sample delivered to the GC?

Headspace vapor moves from the sampler to the GC inlet through a heated transfer line.

Does this system include a warranty?

Yes — this system ships with a 90-day warranty.