Lease/Rent

Agilent 7890B GC with FID, TCD & Dual 7693 Towers

Listing #:LS-006813
Brand:Agilent
Model:7890B, G4513A, G4514A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$29,500.00
In Stock
Make an Offer

Agilent 7890B GC with FID, TCD & Dual 7693 Towers — dual towers inject in under 100ms, sharing a 150-vial tray across both detector channels. Refurbished and tested by Alliant Scientific.

Description

Agilent 7890B GC with FID, TCD & Dual 7693 Towers Overview

The Agilent 7890B GC with FID, TCD & Dual 7693 Towers runs two automated injection methods at once. Each 7693 tower (G4513A) injects into its own inlet, and both towers draw from one shared sample tray (G4514A), so a single sequence can feed both detector channels. The flame ionization detector covers hydrocarbons and other organics, while the thermal conductivity detector covers permanent gases such as nitrogen and carbon dioxide.

Each inlet and detector on the Agilent 7890B GC with FID, TCD & Dual 7693 Towers has its own electronic pneumatic control, so gas flows and pressures are set and held independently and retention times stay repeatable. Fast injection reduces needle discrimination and sample breakdown on volatile or heat-sensitive compounds. The TCD has a single filament, so there is no separate reference gas line and no manual balance adjustment.

Petrochemical, environmental and gas analysis laboratories use the Agilent 7890B GC with FID, TCD & Dual 7693 Towers, and so do high-throughput laboratories that run two methods side by side. This Agilent 7890B GC with FID, TCD & Dual 7693 Towers is offered fully refurbished and tested, in working condition, by Alliant Scientific. It ships with a 90-day warranty, and onsite installation is available on request.

Includes:

  • Agilent 7890B GC (G3440B)
    • FID
    • TCD
    • Two SSL Inlets
  • Dual 7693 Injector Towers (G4513A)
  • 7693 Sample Tray (G4514A)
  • Data System
  • 90-Day Warranty

Looking for Another Configuration?

See the 7890B GC with FID, TCD and dual 7683 towers or the 7890B GC with FID, TCD and S/SL inlets.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 7890B (G3440B)
Detectors FID, TCD
Inlets Two Split/Splitless (SSL)
Autosampler Dual 7693 Towers (G4513A), Sample Tray (G4514A)
Injection Speed Under 100 milliseconds
Response Factor Variation Less than 5% RSD
Vial Tray Capacity Up to 150 vials
Pneumatics Control Electronic Pneumatic Control (EPC), all inlets/detectors
Pressure Metering Precision 0.001 psi
Flow Metering Precision 0.05 mL/min
FID Linear Dynamic Range 10^7
TCD Design Single-filament
TCD Data Acquisition Rate Up to 200 Hz
Oven Temperature Range Ambient +4°C to 450°C
Inlet Sealing System Turn-Top, tool-free liner changes
Capillary Flow Technology Supports Deans-switch, 2D GC, backflush (no cryogen required)
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

, ,

Onsite Installation

Warranty

Key Features

  • Dual Inlet, Dual Detector Configuration
    Two SSL inlets paired with FID and TCD detectors for broad compound coverage in one system.
  • Sub-100ms Injection Speed
    Both 7693 towers inject in under 100 milliseconds, reducing needle discrimination and sample degradation.
  • 150-Vial Shared Tray
    Supports extended, unattended sample runs across both injector towers.
  • Single-Filament TCD
    Eliminates the separate reference gas and manual potentiometer adjustment required by older dual-filament designs.
  • Backflush Without Cryogen
    Capillary Flow Technology enables in-oven backflush, venting heavy matrix before it reaches the detector.

Applications

  • Petrochemical Analysis
    Simultaneous detection of hydrocarbons and permanent gases in one run.
  • High-Throughput Dual-Method Analysis
    Independent towers with sub-100ms injection support running two methods in parallel.
  • Environmental Testing
    Combined organic compound and fixed gas analysis for environmental samples.
  • Gas Analysis
    TCD detection of permanent gases alongside FID detection of organic compounds.

FAQ (Frequently Asked Questions)

How fast do the 7693 towers inject?

Under 100 milliseconds, with response factor variation under 5% RSD.

Do both towers share the same sample tray?

Yes — a single 150-vial sample tray (G4514A) serves both injector towers.

What does the TCD detect that the FID doesn’t?

TCD detects fixed/permanent gases and compounds that don’t ionize in a flame, such as carbon dioxide, nitrogen, and other inorganic gases.

What is Capillary Flow Technology used for?

It enables leak-free, in-oven connections for Deans-switch heart-cutting, two-dimensional GC, and backflush — all without requiring cryogen.

Does this unit include a warranty?

Yes — this unit ships with a 90-day warranty.