Agilent 7890B GC with TCD

Listing #:LS-006953
Brand:Agilent
Model:7890B
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$12,900.00
In Stock
Make an Offer

Agilent 7890B GC with TCD — modular gas chromatograph with one S/SL inlet and one thermal conductivity detector for permanent gas and general GC analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 7890B GC with TCD Overview

The Agilent 7890B is a modular gas chromatograph with electronic pneumatic control (EPC) and high-performance oven temperature control. This configuration has one split/splitless (S/SL) inlet and one thermal conductivity detector (TCD).

The TCD compares the thermal conductivity of the column effluent to a reference gas flow. It responds to organic and inorganic compounds, including permanent gases such as argon, oxygen, nitrogen, and carbon dioxide. Maximum temperature is 400 °C, linear dynamic range is greater than 105, and data rates reach 200 Hz. The S/SL inlet supports split, splitless, and pulsed injection modes at up to 400 °C, with split ratios up to 7,500:1.

This Agilent 7890B GC with TCD is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 7890B GC (G3440B)
      • 1 Split/Splitless (S/SL) Inlet
      • 1 Thermal Conductivity Detector (TCD)
  • Data System
  • 90-Day Warranty

Add a 7693 Autosampler

Automate liquid injections with the Agilent 7693 G4513A Tower and G4514A Autosampler Tray, which holds up to 150 samples.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 7890B GC (G3440B)
Inlet 1 split/splitless (S/SL) inlet
Inlet Maximum Temperature 400 °C
Split Ratio Up to 7,500:1
Total Flow Setting Range 0 to 200 mL/min N2; 0 to 1,000 mL/min H2 or He
Detector 1 thermal conductivity detector (TCD)
TCD Minimum Detectable Level ≤ 400 pg tridecane/mL with He carrier
TCD Linear Dynamic Range > 105 (± 5%)
TCD Maximum Temperature 400 °C
TCD Makeup Gas 0 to 12 mL/min
TCD Reference Gas 0 to 100 mL/min
TCD Data Rate Up to 200 Hz
Pneumatic Control Electronic pneumatic control (EPC), 0.001 psi resolution
Oven Temperature Range Ambient +4 °C to 450 °C
Oven Programming 20 ramps, 21 plateaus
Maximum Ramp Rate 120 °C/min (75 °C/min on 120 V units)
Oven Cool Down 450 to 50 °C in 4.0 min
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Model

Onsite Installation

Warranty

Condition

Key Features

  • Universal TCD Detection
    Responds to organic and inorganic compounds, including permanent gases such as argon, oxygen, nitrogen, and carbon dioxide.
  • Wide TCD Linear Range
    Linear dynamic range above 105 with data rates up to 200 Hz.
  • S/SL Inlet
    Split, splitless, and pulsed injection at up to 400 °C, with split ratios up to 7,500:1.
  • Electronic Pneumatic Control
    EPC meters carrier gas pressure to 0.001 psi for repeatable retention times.
  • Fast Oven
    Cools from 450 to 50 °C in about 4 minutes and ramps up to 120 °C/min.
  • Multi-Ramp Programming
    20 oven ramps and 21 plateaus for complex temperature programs.

Applications

  • Permanent Gas Analysis
    Hydrogen, oxygen, nitrogen, argon, and carbon dioxide determination.
  • Gas Purity Testing
    Detection of impurities in industrial and specialty gases.
  • Natural Gas and Biogas
    Composition analysis of methane, CO2, and light components.
  • General Capillary GC
    Routine separations of compounds that do not respond to a flame detector.

FAQ (Frequently Asked Questions)

What does the TCD detect?

The TCD responds to organic and inorganic compounds, including permanent gases such as argon, oxygen, nitrogen, and carbon dioxide.

How many inlets and detectors does this GC have?

One split/splitless (S/SL) inlet and one thermal conductivity detector (TCD).

What is the maximum oven temperature?

450 °C, with a range starting at ambient +4 °C.

Is an autosampler included?

No — this listing is for the GC only. The 7890B is compatible with the Agilent 7693 autosampler.

What is the maximum TCD temperature?

400 °C.

Does this unit include a warranty?

Yes — this unit ships with a 90-day warranty.