Lease/Rent

Agilent 1290 Infinity II HPLC System

Listing #:LS-004825
Brand:
Model:G7116B, G7117B, G7120A, G7167-60101, G7167B
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$52,500.00
In Stock
Make an Offer

Agilent 1290 Infinity II HPLC System — 1,300 bar UHPLC system with high-speed binary pump, cooled multisampler, multicolumn thermostat and diode array detector for fast pharmaceutical, peptide and cannabis analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 1290 Infinity II HPLC System Overview

The Agilent 1290 Infinity II HPLC System is an ultra-high-pressure liquid chromatograph built for fast, high-resolution separations on small-particle columns. Its high-pressure range lets laboratories run sub-2 µm columns and short gradients, cutting run times while keeping peaks well resolved. The configuration covers both routine testing and method development, with automated sampling, multi-column switching and full-spectrum UV detection in one stack.

In the Agilent 1290 Infinity II HPLC, the binary high-speed pump mixes two solvents at high pressure and delivers the gradient through a low-volume flow path, so the gradient reaches the column quickly and peaks stay narrow. The multisampler draws each sample from a vial or well plate held in its cooled thermostat and injects it into the flow. The multicolumn thermostat holds several columns at set temperatures and switches between them under software control. As compounds elute, the diode array detector records full UV-Vis spectra at a high data rate, which captures the narrow peaks UHPLC produces and supports peak purity checks.

Pharmaceutical QC, biopharma, contract research, cannabis testing and food and beverage laboratories use the Agilent 1290 Infinity II HPLC System for impurity profiling, stability studies, peptide purity testing, cannabinoid potency testing, and method development and validation. The system can also serve as the front end for an LC-MS system.

This Agilent 1290 Infinity II HPLC System is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Agilent 1290 Infinity II HPLC System
    • G7120A High-Speed Pump
    • G7167B Multisampler with G7167-60101 Sample Thermostat
    • G7116B Multicolumn Thermostat (MCT)
    • G7117B Diode Array Detector (DAD)
  • Dell PC with Windows 11 Pro and Data System
  • 90-Day Warranty

Browse our full HPLC inventory for other UHPLC and HPLC systems, or pair this system with a mass spectrometer from our LC-MS inventory.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 1290 Infinity II HPLC System
Pump (G7120A) Binary high-speed pump, up to 1,300 bar, up to 5 mL/min
Autosampler (G7167B) Multisampler for vials and well plates, up to 1,300 bar, 20 µL injection loop
Sample Cooling (G7167-60101) Active sample thermostat
Column Compartment (G7116B) Multicolumn thermostat, 4 to 110 °C, up to 8 columns
Detector (G7117B) Diode array detector, 10 mm flow cell, up to 240 Hz
Data System Dell PC with Windows 11 Pro
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

, , , ,

Onsite Installation

Warranty

Key Features

  • Up to 1,300 bar – Runs sub-2 µm columns for fast, high-resolution UHPLC separations.
  • Binary Pump, up to 5 mL/min – Fast, precise gradients for method development and routine work.
  • Multisampler with Thermostat – Automated injection from vials and plates, with cooled sample storage.
  • Multicolumn Thermostat, 4 to 110 °C – Holds several columns and switches between them.
  • DAD up to 240 Hz – Full UV-Vis spectra for narrow UHPLC peaks and peak purity checks.
  • LC-MS Ready – Works as the front end for an Agilent mass spectrometer.

Applications

  • Pharmaceutical Quality Control – QC laboratories run assay, impurity and related-substance methods on fast UHPLC gradients to raise sample throughput.
  • Peptide Testing – Peptide manufacturers and biopharma QC groups measure peptide purity by UV detection at 214 or 220 nm.
  • Cannabis and Hemp Testing – Cannabis testing laboratories quantify THC, CBD and other cannabinoids in flower, concentrates and edibles.
  • Method Development and Validation – Analytical development groups screen columns and gradients automatically using multicolumn switching.
  • Stability Studies – Pharmaceutical laboratories monitor degradation products in stability samples over time.
  • Food, Beverage and Nutraceutical Testing – Food and supplement laboratories measure additives, vitamins and active ingredients.

Frequently Asked Questions

What does the Agilent 1290 Infinity II HPLC System include?

A high-speed binary pump, multisampler with sample thermostat, multicolumn thermostat, diode array detector and a Dell PC with data system.

What is the maximum pressure?

Up to 1,300 bar.

How many columns can the column compartment hold?

Up to eight, at 4 to 110 °C.

Are samples temperature controlled?

Yes. The multisampler has an active sample thermostat.

Can it run peptide purity or cannabis potency testing?

Yes. Both are standard UV-detection methods covered by the DAD.

Does it include a mass spectrometer?

No. This listing is the LC only.

What warranty does it have?

The system is refurbished and tested, and it ships with a 90-day warranty.