Agilent 1200 HPLC System with Binary Pump SL and DAD SL — binary gradient HPLC with a G1312B Binary Pump SL, G1315C DAD SL, cooled 100-vial autosampler and column compartment for fast separations with full-spectrum UV-Vis detection. Refurbished and tested by Alliant Scientific.

Description

Agilent 1200 HPLC System with Binary Pump SL Overview

The Agilent 1200 HPLC System with Binary Pump SL is a complete binary gradient system built around the two higher-performance SL modules of the 1200 Series: the G1312B Binary Pump SL and the G1315C DAD SL. The pump can run with a 120 µL low-delay flow path, so gradients reach the column faster and short methods finish sooner. The DAD SL records full UV-Vis spectra at up to 80 Hz, fast enough to capture the narrow peaks of short, high-efficiency columns. A thermostatted autosampler and a column compartment complete the system for unattended, temperature-controlled runs.

How the System Works

The G1322A degasser removes dissolved gas from both solvent channels before they reach the G1312B pump, where two dual-piston pumps in series mix the gradient at high pressure. The G1329A autosampler injects from up to 100 vials while the G1330B thermostat keeps samples cooled in the tray. Separation takes place in the G1316A column compartment, which holds the column at a set temperature with a pre-heater for consistent retention times. The G1315C DAD SL then measures absorbance across the full wavelength range at every point, and RFID tags on its lamp and flow cell log usage and cell type automatically.

This Agilent 1200 HPLC System with Binary Pump SL and DAD SL is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Agilent 1200 HPLC System
    • G1322A Degasser
    • G1312B Binary Pump SL
    • G1329A Autosampler
    • G1330B ALS Thermostat
    • G1316A Thermostatted Column Compartment
    • G1315C DAD SL
    • Tray
    • Data System
  • 90-day warranty

Looking for the standard version? See the Agilent 1200 HPLC System with Binary Pump G1312A and DAD G1315B, or browse more refurbished HPLC systems.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Agilent 1200 HPLC System with Binary Pump SL Specifications

Manufacturer Agilent
Series 1200
Condition Refurbished
Pump G1312B Binary Pump SL, high-pressure binary mixing
Pump Pressure Rating 0–600 bar
Flow Range 0.05–5.0 mL/min
Delay Volume 600–800 µL standard; 120 µL low-delay configuration
Composition Precision <0.15% RSD at 1 mL/min
Degasser G1322A vacuum degasser
Autosampler G1329A, 100 x 2 mL vials
Sample Cooling G1330B ALS thermostat
Column Compartment G1316A thermostatted column compartment
Detector G1315C DAD SL
Wavelength Range 190–950 nm
Data Rate Up to 80 Hz
Slit Programmable
Lamp/Flow Cell ID RFID tags
System Pressure Limit 400 bar (set by the G1329A autosampler and G1316A column compartment)
Warranty 90 days

Additional information

Availability

Brand

Condition

Onsite Installation

Warranty

Model

, , , , ,

Agilent 1200 HPLC System with Binary Pump SL Key Features

  • 120 µL low-delay flow path: faster gradient delivery and shorter run-to-run times.
  • 80 Hz DAD SL: full-spectrum detection fast enough for narrow peaks from short columns.
  • 190–950 nm range: UV and visible detection with peak purity and spectral library matching.
  • <0.15% RSD composition precision: reproducible gradients and retention times.
  • 100-vial autosampler: unattended batches with cooled sample storage.
  • Thermostatted column compartment: stable column temperature for consistent separations.
  • High-pressure binary mixing: two pumps in series for accurate two-solvent gradients.
  • RFID-tagged lamp and flow cell: automatic tracking of lamp hours and cell type.

Agilent 1200 HPLC System with Binary Pump SL Applications

  • Pharmaceutical QC labs: assay, impurity and dissolution testing with peak purity checks by DAD.
  • Method development groups: fast gradient screening using the low-delay pump configuration.
  • Cannabis testing labs: cannabinoid potency profiling by HPLC with UV detection.
  • Food and beverage labs: analysis of additives, preservatives, sweeteners and vitamins.
  • Chemical and polymer manufacturers: purity checks and additive analysis on raw materials and products.
  • LC/MS labs: a binary LC front end with low delay volume for mass spectrometry methods.
  • University research labs: routine separations and teaching on a full-featured gradient system.

Agilent 1200 HPLC System with Binary Pump SL FAQ

What is the difference between the G1312B and G1312A binary pumps?
The G1312B Binary Pump SL is rated to 600 bar and supports a 120 µL low-delay configuration; the G1312A is rated to 400 bar.

What is the DAD SL data rate?
Up to 80 Hz.

What wavelength range does the detector cover?
190–950 nm.

What is the maximum system pressure?
400 bar, set by the standard autosampler and column compartment.

How many samples does the autosampler hold?
100 x 2 mL vials, with cooling from the G1330B thermostat.

Is this system refurbished?
Yes. It is refurbished and tested by Alliant Scientific, with a 90-day warranty.