Lease/Rent

Agilent 1260 Infinity G1364C FC-AS

Listing #:LS-007044
Brand:Agilent
Model:G1364C
Availability:In Stock
Condition:Refurbished
Warranty:30 Days
Onsite Installation:Available upon request
$4,250.00
In Stock
Make an Offer

Agilent 1260 Infinity G1364C FC-AS — analytical-scale fraction collector for 100 µL/min to 10 mL/min with a fraction delay sensor and time or peak triggering. Refurbished and tested by Alliant Scientific.

Description

Agilent 1260 Infinity G1364C FC-AS Overview

The Agilent 1260 Infinity G1364C FC-AS is an analytical-scale fraction collector designed for flow rates from 100 µL/min to 10 mL/min. Maximum flow is 10 mL/min, depending on viscosity and back pressure, with a limit of 6 bar at the diverter valve. It can also be modified for flows above 10 mL/min.

Collection can be triggered by time slices, by peaks (threshold, upslope, or downslope), by a timetable that combines both, or manually with the Instant Pilot (G4208A). The collector is fully supported with 1260 Infinity DAD and MWD detectors, the 1260 Infinity fluorescence detector (G1321A), and Agilent LC/MSD systems.

The tray options cover a wide range of vessels: 100 x 2 mL vials, well plates, half trays of 2 mL or 6 mL vials, 40-funnel trays for external containers, and a full tray of 40 test tubes up to 30 mm OD.

This Agilent 1260 Infinity G1364C FC-AS is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 1260 Infinity G1364C FC-AS
    • Tray
  • 30-Day Warranty

Looking for a Complete HPLC System?

Pair this collector with our Agilent 1260 Infinity HPLC System with DAD, or browse our full HPLC inventory for other configurations.

Listing last updated: October 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 1260 Infinity Analytical-Scale Fraction Collector (G1364C, FC-AS)
Flow Rate Range 100 µL/min to 10 mL/min
Maximum Flow Rate 10 mL/min (max. 6 bar at the diverter valve); modifiable for higher flow
Trigger Modes Time slices, peak (threshold, up-/downslope), timetable, manual (with Instant Pilot G4208A)
Operating Modes Discrete fractions, continuous flow, needle into location, droplet setup
Delay Volumes Inlet to diverter valve ~50 µL; diverter valve ~15 µL; valve to needle ~10 µL; needle ~4 µL
Delay Calibration Sensor Single-wavelength absorbance detector, 654 nm (LED and photodiode)
Tray Options 100 x 2 mL vials; 2 well plates + 10 x 2 mL vials; 4 well plates; half trays of 40 x 2 mL, 40 funnels, or 15 x 6 mL; full tray of 40 test tubes (30 mm OD)
Maximum Vessel Height 48 mm (standard needle assembly); 75 mm (short needle assembly)
Maximum Tube Volume About 20 mL (48 mm tubes); 30 mL (75 mm tubes); unlimited with funnels and external containers
Supported Detectors 1260 Infinity DAD/MWD, 1260 Infinity FLD (G1321A), Agilent LC/MSD
Safety Features Leak detection, exhaust fan for fume extraction, error display
Power Requirements 100 to 240 VAC (± 10%), 50/60 Hz
Dimensions (H x W x D) 200 x 345 x 440 mm
Weight 13.5 kg (29.8 lb)
Condition Refurbished and tested
Warranty 30 days

Additional information

Availability

Condition

Model

Warranty

Brand

Onsite Installation

Key Features

  • Fraction Delay Sensor
    Determines delay volumes automatically so fractions are collected just in time.
  • Low Delay Volumes
    About 50 µL from the inlet to the diverter valve and 4 µL in the needle limit peak broadening.
  • Flexible Triggering
    Time slices, peak-based, timetable, or manual collection.
  • Droplet Setup Mode
    Collects small fractions without bubbles.
  • Wide Tray Selection
    Vials, well plates, test tubes, and funnels, with automatic tray detection.
  • Parallel and Recovery Collection
    Run up to three collectors in parallel plus one recovery collector.
  • Safe Handling
    Leak detection and an exhaust fan for hazardous vapors.

Applications

  • Analytical-Scale Purification
    Collect target compounds from analytical and semi-micro HPLC runs.
  • Impurity Isolation
    Capture trace impurities and degradants for follow-up identification.
  • Off-Line MS and NMR Sample Collection
    Collect fractions for characterization by mass spectrometry or NMR.
  • Method Development
    Peak-based collection confirms what elutes in each peak.

FAQ (Frequently Asked Questions)

What flow rates does the G1364C support?

100 µL/min to 10 mL/min, and it can be modified for flows above 10 mL/min.

How does the collector time fractions correctly?

A built-in fraction delay sensor measures the delay volume automatically, so fractions are collected just in time.

What trigger modes are available?

Time slices, peak (threshold, up-/downslope), timetable, and manual (with the Instant Pilot G4208A).

What detectors does it support?

1260 Infinity DAD and MWD detectors, the 1260 Infinity fluorescence detector (G1321A), and Agilent LC/MSD systems.

What fraction containers can I use?

2 mL and 6 mL vials, well plates, test tubes up to 30 mm OD, and funnels for external containers.

Does this unit include a warranty?

Yes — this unit ships with a 30-day warranty.