Agilent 8890 GC with PAL RSI 120 Autosampler — 8890 gas chromatograph with dual SSL inlets, dual flame ionization detectors and a robotic PAL RSI 120 autosampler for two-channel GC-FID analysis. Refurbished and tested by Alliant Scientific.

Description

Agilent 8890 GC PAL RSI 120 Overview

The Agilent 8890 GC PAL RSI 120 system pairs an 8890 gas chromatograph with two split/splitless (SSL) inlets and two flame ionization detectors (FID) with a PAL RSI 120 robotic autosampler. Two inlet-to-detector channels mean two columns can run in parallel: either two different methods, or one sample injected on two columns of different polarity to confirm peak identity. Each FID detects below 1.0 pg C/s and acquires data at up to 1,000 Hz. The oven reaches 450 °C with up to 32 ramps, so one program can cover a wide boiling range.

The PAL RSI 120 handles the sample side of the Agilent 8890 GC PAL RSI 120 system. It is a gantry-style robotic sampler, not a fixed tower, so it moves vials between the tray, the cool stack and the wash station before each injection. The cool stack keeps samples in drawers at the instrument, the wash station rinses the syringe between samples, and the tray holder takes the vial trays. With a capacity of up to 120 vials, a full sequence runs unattended. A handheld controller sets up the sampler at the instrument.

Petrochemical and fuel laboratories running hydrocarbon analysis, environmental labs testing volatile organic compounds, pharmaceutical groups checking residual solvents and raw materials, food and beverage labs profiling flavor and aroma, and chemical manufacturers use the Agilent 8890 GC PAL RSI 120 for routine GC-FID work with two channels.

This Agilent 8890 GC PAL RSI 120 Autosampler is offered fully refurbished and tested, in working condition, by Alliant Scientific. It ships with a 90-day warranty, and onsite installation is available on request.

Includes:

  • Agilent 8890 Gas Chromatograph
    • Dual Split/Splitless (SSL) Inlets
    • Dual Flame Ionization Detectors (FID)
  • PAL RSI 120 Autosampler
    • Injector
    • 3-Drawer Cool Stack
    • Wash Station
    • Handheld Controller
    • Tray Holder with Trays
    • Power Supplies
  • Data System

Optional:

  • Premium Refurbishment with Extended Warranty

Looking for Other Gas Chromatographs?

Browse our full GC inventory for other GC, GC-FID and GC-MS systems.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies (GC); CTC Analytics (autosampler)
GC Model 8890 GC
Inlets Dual split/splitless (SSL), up to 400 °C; split ratio up to 13,500:1
Detectors Dual flame ionization detectors (FID)
FID Detection Limit Below 1.0 pg C/s
FID Linear Range Greater than 10^7
FID Data Rate Up to 1,000 Hz
Gas Control Electronic pneumatics control (EPC)
Oven Temperature Ambient +4 to 450 °C
Oven Programming Up to 32 ramps and 33 plateaus
Oven Cool-Down To 22 °C in about 2.0 to 3.4 minutes, depending on configuration
Autosampler PAL RSI 120 robotic autosampler
Vial Capacity Up to 120 vials
Autosampler Includes Injector, 3-drawer cool stack, wash station, tray holder with trays, handheld controller
Power 100 to 240 VAC, 50/60 Hz
Data System Included
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

,

Onsite Installation

Warranty

Key Features

  • Dual Inlets and Dual FIDs
    Two independent channels for parallel methods or two-column confirmation.
  • FID Below 1.0 pg C/s
    Sensitive detection of hydrocarbons and organic compounds.
  • 1,000 Hz Data Rate
    Defines very narrow peaks.
  • Split Ratio up to 13,500:1
    Handles concentrated samples on either inlet.
  • Up to 32 Oven Ramps
    Detailed temperature programs for complex mixtures.
  • PAL RSI 120 Robotic Sampler
    Moves vials between the tray, cool stack and wash station.
  • Up to 120 Vials
    Long unattended sequences.
  • 3-Drawer Cool Stack
    Holds samples at the instrument until injection.

Applications

  • Hydrocarbon and Fuel Analysis
    Petrochemical streams and QC.
  • Environmental Testing
    Volatile organic compounds and contaminants.
  • Residual Solvents
    Pharmaceutical products and raw materials.
  • Flavor and Aroma
    Food and beverage profiling.
  • Chemical Manufacturing QA
    Batch and process testing.
  • Two-Column Confirmation
    Confirm identity by retention on two channels.

FAQ (Frequently Asked Questions)

What does this system include?

An Agilent 8890 GC with dual SSL inlets and dual FIDs, a PAL RSI 120 autosampler and a data system.

How many vials does the autosampler hold?

Up to 120 vials.

Can it run two methods at once?

Yes. Each channel has its own inlet and detector.

What is the FID detection limit?

Below 1.0 pg C/s.

What is the maximum oven temperature?

450 °C.

Does this system include a warranty?

Yes. It ships with a 90-day warranty.