Lease/Rent

Agilent 8890 GC-FID with 7693 Autosampler

Listing #:LS-005744
Brand:Agilent
Model:8890, G4513A, G4514A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$37,900.00
In Stock
Make an Offer

Agilent 8890 GC-FID with 7693 Autosampler — single-FID gas chromatograph with a split/splitless inlet and a 7693 autosampler with tray for unattended hydrocarbon and VOC sequences. Refurbished and tested by Alliant Scientific.

Description

Agilent 8890 GC FID Autosampler System Overview

This Agilent 8890 GC FID autosampler system is an 8890 gas chromatograph with a single split/splitless (SSL) inlet and a single flame ionization detector (FID), fitted with a 7693 autosampler. The oven runs from ambient +4 °C to 450 °C, and the inlet operates up to 400 °C. Electronic pneumatic control (EPC) holds pressure to about ±0.001 psi, and the FID has a linear dynamic range above 107.

The G4513A injector tower and G4514A tray hold up to 150 vials in three removable 5 x 10 racks. The standard syringe carriage accepts syringes from 1 µL to 100 µL, covering injections from 10 nL to 50 µL, and a fast injection takes under 100 ms. Agilent specifies area reproducibility better than 0.3% RSD and carryover below 1 part in 100,000. The system needs a carrier gas (helium, hydrogen or nitrogen), plus hydrogen, air and makeup gas for the FID.

This Agilent 8890 GC FID autosampler system is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 8890Gas Chromatograph
    • Single Split/Splitless (SSL) Inlet
    • Single Flame Ionization Detector (FID)
  • Agilent 7693 Autosampler
    • G4513A Injector Tower
    • G4514A Sample Tray
  • Data System
  • 90-Day Warranty

Looking for Other Gas Chromatographs?

Browse our full gas chromatography inventory for other configurations.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 8890 GC (8890A) with 7693 autosampler
Instrument Type Gas chromatograph with flame ionization detector
Autosampler 7693 with G4513A injector tower and G4514A tray
Sample Capacity 150 vials (three removable 5 x 10 racks)
Vial Type Standard 2 mL vials
Syringe Sizes 1 to 100 µL (standard syringe carriage)
Injection Volume 10 nL to 50 µL
Injection Speed Fast injection in under 100 ms
Area Reproducibility Better than 0.3% RSD (C10–C16, 1 µL injection, 10 injections)
Carryover Less than 1 part in 100,000
Inlet Single split/splitless (SSL), up to 400 °C, EPC
Inlet Pressure Range 0 to 100 psig (columns 0.200 mm ID or larger)
Split Ratio Up to 13,500:1
Detector Single flame ionization detector (FID)
FID Linear Range Above 107
FID Gas Flows Air 0 to 800 mL/min; hydrogen 0 to 100 mL/min; makeup (nitrogen or helium) 0 to 100 mL/min
Oven Temperature Range Ambient +4 °C to 450 °C, 0.1 °C setpoint resolution
EPC Pressure Control About ±0.001 psi (typical)
Carrier Gas Helium, hydrogen or nitrogen
Display 7-inch capacitive touchscreen
Interfaces LAN, analog outputs, remote start/stop
Dimensions (H x W x D) 49 x 58 x 51 cm (19.2 x 22.9 x 20.2 in), GC only
Weight 49 kg (108 lb), GC only
Power 120/200/220/230/240 V ±10%, 50/60 Hz
Operating Temperature 15 to 35 °C
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

, ,

Onsite Installation

Warranty

Key Features

  • 150-Vial Tray
    Three removable 5 x 10 racks hold a full sequence of samples, standards and blanks.
  • 10 nL to 50 µL Injections
    Syringes from 1 µL to 100 µL cover trace and routine injection volumes.
  • Fast, Clean Injections
    Sub-100 ms injections with carryover below 1 part in 100,000.
  • FID Linear Range Above 107
    Trace and high-level samples quantify in the same batch.
  • 450 °C Oven
    Ambient +4 °C to 450 °C with 0.1 °C setpoint resolution.
  • EPC Gas Control
    Pressure holds to about ±0.001 psi for stable retention times.
  • 7-Inch Touchscreen
    Local control, with LAN connection to the data system.

Applications

  • Fuel and Petrochemical Labs
    Hydrocarbon profiling across large sample batches.
  • Environmental Testing
    VOC and semi-volatile screening in water and soil extracts.
  • Pharmaceutical QC
    Impurity and residual solvent methods run in sequence.
  • Food and Flavor Testing
    Volatile flavor and aroma components across many samples.
  • Forensic and Toxicology Labs
    Volatile and semi-volatile compound analysis.
  • Chemical Manufacturing
    Routine purity checks and process monitoring.

FAQ (Frequently Asked Questions)

How many vials does the tray hold?

150 vials, in three removable 5 x 10 racks.

What injection volumes does the autosampler cover?

10 nL to 50 µL, using syringes from 1 µL to 100 µL.

What is the oven temperature range?

Ambient +4 °C to 450 °C.

What can the FID detect?

Hydrocarbons and most organic compounds. It does not respond to water, carbon dioxide or most permanent gases.

What gases does the system need?

A carrier gas (helium, hydrogen or nitrogen), plus hydrogen, air and makeup gas for the FID.

How is this different from the tower-only 8890?

The tower-only system has the same GC and detector but no tray, so it does not run queued sequences.

Does this unit include a warranty?

Yes — this unit ships with a 90-day warranty.