Lease/Rent

Agilent 1260 Infinity II HPLC System with DAD

Listing #:LS-004856
Brand:
Model:G7112B, G7115A, G7116A, G7129A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$34,500.00
In Stock
Make an Offer

Agilent 1260 Infinity II HPLC System with DAD — 600 bar binary HPLC with vialsampler, sample thermostat, multicolumn thermostat and diode array detector for UV quantitation and peak purity. Refurbished and tested by Alliant Scientific.

Description

Agilent 1260 Infinity II HPLC System with DAD Overview

The Agilent 1260 Infinity II HPLC System with DAD is a complete binary-pump HPLC configured for UV quantitation and spectral confirmation in one run. The binary pump forms gradients by high-pressure mixing, so retention times hold steady from run to run and methods transfer cleanly between systems. A sample thermostat keeps vials at a controlled temperature through long overnight sequences, and the multicolumn thermostat holds the column at a set temperature. The diode array detector records a full UV-Vis spectrum at every point of every peak.

In the Agilent 1260 Infinity II HPLC System with DAD, two independent pumping channels each deliver one solvent, and the streams combine after the pumps at up to 600 bar. The vialsampler uses a flow-through needle design, in which the needle stays in the mobile phase path after injection and is flushed by every gradient. Separated compounds then pass through the DAD flow cell, where light from deuterium and tungsten lamps is spread by a grating across a photodiode array, so all wavelengths are measured at once rather than one at a time.

Pharmaceutical QC laboratories use the Agilent 1260 Infinity II HPLC System with DAD for assay, impurity, stability and dissolution testing, with peak purity checks from the spectral data. Peptide manufacturers run purity methods, cannabis testing laboratories run cannabinoid potency methods, and food and nutraceutical laboratories measure vitamins, additives and active ingredients. Chemical manufacturers and university departments also rely on the Agilent 1260 Infinity II HPLC System with DAD for routine analysis and method development.

This Agilent 1260 Infinity II HPLC System with DAD is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Agilent 1260 Infinity II HPLC System
    • G7112B Binary Pump
    • G7129A Vialsampler
      • G7167-60101 Sample Thermostat
    • G7116A Multicolumn Thermostat (MCT)
    • G7115A Diode Array Detector WR (DAD)
    • Solvent Tray
  • Dell PC with Windows 11 Pro and Data System
  • 90-Day Warranty

Optional:

  • Module Customization
  • Premium Refurbishment with Extended Warranty

Alternatives to the Agilent 1260 Infinity II HPLC System with DAD are listed in our full HPLC inventory

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Series 1260 Infinity II
Pump (G7112B) Binary pump, high-pressure mixing
Maximum Pressure 600 bar (8,700 psi)
Flow Rate Range 0.001 to 5 mL/min
Sampler (G7129A) Vialsampler, flow-through needle
Sample Thermostat G7167-60101
Column Thermostat (G7116A) Multicolumn thermostat
Detector (G7115A) Diode array detector WR, 190 to 950 nm
Data System Dell PC with Windows 11 Pro
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

, , ,

Onsite Installation

Warranty

Key Features

  • Binary Pump to 600 bar – The Agilent 1260 Infinity II HPLC System with DAD runs conventional and sub-2 µm columns.
  • High-Pressure Mixing – Steady retention times and clean method transfer.
  • Flow-Through Needle Vialsampler – Needle flushed by every gradient.
  • Sample Thermostat – Controlled vial temperature for long sequences.
  • DAD, 190 to 950 nm – Full spectra for quantitation and peak purity.
  • Multicolumn Thermostat – Stable column temperature.

Applications

  • Pharmaceutical QC – QC laboratories run assay, impurity, stability and dissolution methods with peak purity checks.
  • Peptide Testing – Peptide manufacturers use the Agilent 1260 Infinity II HPLC System with DAD for reversed-phase purity analysis.
  • Cannabis Testing – Cannabis and hemp laboratories run cannabinoid potency methods by UV.
  • Food and Nutraceuticals – Food and supplement laboratories measure vitamins, additives and active ingredients.
  • Chemical Analysis – Chemical manufacturers check product purity and composition.
  • Method Development and Teaching – University departments use the system for HPLC instruction and method work.

Frequently Asked Questions

What does the Agilent 1260 Infinity II HPLC System with DAD include?

G7112B binary pump, G7129A vialsampler with sample thermostat, G7116A multicolumn thermostat, G7115A DAD, solvent tray and a Dell PC with data system.

What is the maximum pressure?

600 bar (8,700 psi).

What is the flow rate range?

0.001 to 5 mL/min.

What wavelength range does the Agilent 1260 Infinity II HPLC System with DAD cover?

190 to 950 nm.

What warranty does it have?

The system is refurbished and tested, and it ships with a 90-day warranty.