Lease/Rent

Agilent 1100 HPLC System with Quaternary Pump (G1311A) and FLD Detector (G1321A)

Listing #:LS-004924
Brand:Agilent
Model:1100 Series G1311A, G1321A, G1313A, G1316A, G1322A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$12,500.00
In Stock
Make an Offer

Description

For laboratories handling growing sample loads, the Agilent 1100 HPLC System with Quaternary Pump (G1311A) and FLD Detector (G1321A) delivers reliable, high‑performance chromatography without increasing complexity. Precise gradient control, sensitive fluorescence detection, and an intuitive interface ensure fast, reproducible results—making it an ideal solution for pharmaceutical, environmental, and biochemical analysis.

This refurbished system has been fully tested and verified to be in proper working condition by Alliant Scientific.

System Includes:

  • Agilent 1100 HPLC System
    • Agilent G1322A Degasser
    • Agilent G1311A Quaternary Pump
    • Agilent G1313A Autosampler
    • Agilent G1316A TCC
    • Agilent G1321A Fluorescence Detector (FLD)
    • Solvent Tray
    • Cables & Connectors
  • Dell Windows 11 PC loaded with Data System
  • Warranty Coverage

 

Agilent 1100 HPLC System – Product Specifications

Agilent G1311A Quaternary Pump

  • Pump Type: Low‑pressure quaternary gradient pump
  • Maximum Pressure: 400 bar (5,800 psi)
  • Flow Rate Range: 0.001 – 10.0 mL/min
  • Flow Precision: ≤ 0.07% RSD
  • Gradient Capability: Up to 4 solvents
  • Typical Applications: Gradient and isocratic HPLC methods
  • Compatibility: Fully compatible with all Agilent 1100 Series modules

Agilent G1321A Fluorescence Detector (FLD)

  • Detection Type: Fluorescence
  • Excitation Wavelength Range: 200 – 700 nm
  • Emission Wavelength Range: 200 – 700 nm
  • Sensitivity: High sensitivity for trace‑level fluorescent compounds
  • Light Source: Xenon flash lamp
  • Application Focus: Pharmaceuticals, environmental, food, and biochemical analysis

Agilent G1313A Autosampler

  • Injection Volume Range: 0.1 – 100 µL (programmable)
  • Sample Capacity: Up to 100 vials (standard 2 mL)
  • Injection Precision: ≤ 0.5% RSD
  • Sample Cooling: Optional (depending on configuration)
  • Carryover: < 0.01%

Agilent G1316A Thermostatted Column Compartment (TCC)

  • Temperature Range: 10°C below ambient to 80°C
  • Temperature Stability: ± 0.15°C
  • Column Capacity: Up to 4 columns
  • Heat Exchange: Active heating and cooling
  • Purpose: Improved retention time reproducibility

Agilent G1322A Vacuum Degasser

  • Number of Channels: 4
  • Technology: Continuous vacuum degassing
  • Flow Compatibility: Supports high‑flow HPLC operation
  • Benefit: Reduced baseline noise and improved pump performance

Additional information

Condition

Model

Onsite Installation

Warranty

Brand

Availability