Waters BioAccord LC/MS System

Listing #:LS-007636
Brand:
Model:BioAccord, RDa
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
In Stock

Waters BioAccord LC/MS System — compact accurate-mass time-of-flight LC/MS for intact mass, subunit and peptide mapping analysis of proteins and biotherapeutics. Refurbished and tested by Alliant Scientific.

Description

Waters BioAccord LC/MS System Overview

The Waters BioAccord LC/MS System is a compact, benchtop time-of-flight mass spectrometer built for routine accurate-mass analysis of proteins, peptides and other biotherapeutics. Waters designed it so that analysts who are not mass spectrometry specialists can run it: guided setup, automated calibration and pre-programmed system checks replace the manual tuning a research-grade TOF normally needs. That makes the Waters BioAccord LC/MS a practical way to bring intact mass, subunit and peptide mapping data into development and QC labs, without dedicating an MS expert to the instrument.

How the BioAccord Works

Eluent from the LC enters an electrospray source through a ZSpray dual-orthogonal interface, which keeps neutral contaminants out of the ion path. The ions are measured by a high-stability time-of-flight analyzer at a resolution above 10,000 FWHM, the same detector design Waters also sold as the ACQUITY RDa. An integrated fluidics system delivers calibration and lock mass solutions from on-board reservoirs, so the instrument calibrates itself and holds mass accuracy within 2.5 ppm RMS. Four standardized acquisition modes cover low and high mass ranges in positive and negative ionization, from peptides and small molecules up to the charge states of intact antibodies.

This Waters BioAccord LC/MS System is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Waters BioAccord LC/MS System
    • ESI Source
    • Vacuum pump
    • PC with data system
  • 90-day warranty

Browse more refurbished LC/MS systems

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Waters. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Waters BioAccord LC/MS System Specifications

Manufacturer Waters
Model BioAccord LC/MS System
Condition Refurbished
Analyzer Time-of-flight (TOF)
Ion Source Electrospray (ESI), ZSpray dual-orthogonal interface
Resolution >10,000 FWHM
Mass Accuracy <2.5 ppm RMS (with lock mass)
Low Mass Range Up to m/z 2000 (positive and negative)
High Mass Range Up to m/z 7000 (positive), up to m/z 5000 (negative)
Scan Rate Up to 20 Hz
Calibration Automated, integrated fluidics with on-board reservoirs
Setup Guided setup, automated system checks
Vacuum Pump Included
Data System PC with data system and monitor included
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

,

Onsite Installation

Warranty

Waters BioAccord LC/MS System Key Features

  • >10,000 FWHM TOF resolution: accurate-mass data for proteins, peptides and small molecules.
  • <2.5 ppm mass accuracy: lock mass correction for confident mass confirmation.
  • High mass mode to m/z 7000: covers the charge states of intact antibodies and subunits.
  • 4 standardized acquisition modes: low and high mass in positive and negative ionization.
  • Integrated fluidics: on-board calibrant and lock mass delivery for automatic calibration.
  • Guided setup: designed for analysts who are not MS specialists.
  • Up to 20 Hz scan rate: fast enough for sharp UPLC peaks.
  • Compact benchtop design: accurate-mass LC/MS in a small footprint.

Waters BioAccord LC/MS System Applications

  • Biopharmaceutical development labs: intact mass and glycoform profiling of monoclonal antibodies.
  • Biologics QC labs: routine identity and subunit mass checks on antibody products.
  • Peptide labs: peptide mapping of therapeutic proteins and accurate-mass confirmation of peptides.
  • Oligonucleotide developers: intact mass confirmation and purity analysis of oligonucleotide therapeutics.
  • Pharmaceutical analytical labs: impurity identification and forced degradation studies.
  • Natural products and lipid research labs: accurate-mass screening, library searching and lipid profiling.
  • Forensic labs: accurate-mass identification in seized drug analysis.

Waters BioAccord LC/MS System FAQ

What type of mass spectrometer is the BioAccord?
A benchtop electrospray time-of-flight (TOF) mass spectrometer.

What resolution does it provide?
Above 10,000 FWHM.

What is the mass accuracy?
Below 2.5 ppm RMS with lock mass correction.

Can it measure intact antibodies?
Yes. The high mass mode reaches m/z 7000 in positive ion mode.

Is an LC included?
No. The LC front end is not included; the BioAccord was designed to run with a Waters ACQUITY UPLC.

What is included?
The BioAccord LC/MS System, vacuum pump, PC with data system and monitor, and a 90-day warranty.