Thermo TRACE 1310 GC‑MS/MS System with TSQ 8000 Triple Quad & 1310 AI/AS Autosampler
Description
Thermo TRACE 1310 GC‑MS/MS System with TSQ 8000 Triple Quad & 1310 AI/AS Autosampler Overview
The Thermo TRACE 1310 GC‑MS/MS system, configured with the TSQ 8000 Triple Quadrupole Mass Spectrometer and 1310 AI/AS autosampler, is a high-performance analytical platform engineered for precise, ultra-trace chemical analysis in demanding laboratory environments. This integrated system combines advanced Gas Vhromatographic separation with highly sensitive tandem mass spectrometry detection, enabling exceptional selectivity, accuracy, and reproducibility across complex sample matrices. The TSQ 8000’s triple quadrupole architecture supports targeted quantitation using SRM/MRM, significantly reducing background interference while achieving sub‑ppb detection limits for trace-level compounds. The TRACE 1310 GC is designed for flexibility and consistency, featuring a modular architecture, fast oven temperature programming, and electronic pneumatic control (EPC) for precise gas flow management. These capabilities ensure stable retention times and reliable performance across extended analytical runs.
This GC‑MS/MS configuration is well-suited for a broad spectrum of applications, including pesticide residue analysis, environmental contaminant monitoring, food safety testing, pharmaceutical impurity profiling, forensic toxicology, and petrochemical characterization. Its combination of sensitivity, robustness, and automation makes it an ideal solution for laboratories requiring reliable quantitative results, operational efficiency, and compliance with stringent regulatory methods.
This TRACE 1310 GC‑MS/MS System with TSQ 8000 Triple Quad & 1310 AI/AS Autosampler is offered fully refurbished and tested, in working condition by Alliant Scientific.
Includes:
- Thermo Trace 1310 Gas Chromatograph (GC)
- Single Flame Ionization Detector (FID)
- Thermo TSQ 8000 Triple Quad
- Thermo 1310 AI/AS Autosampler
- Vacuum Pump
- Data System
- 60-Day Warranty Coverage
Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer of the original manufacturer. Software, if included, is not transferable or upgradable
Technical Specifications
| General | |
|---|---|
| Instrument Type | Gas Chromatography–Tandem Mass Spectrometry (GC‑MS/MS) |
| GC Model | TRACE 1310 |
| Mass Spectrometer | TSQ 8000 Triple Quadrupole |
| Autosampler | TriPlus 1310 AI/AS |
| Ionization Mode | Electron Ionization (EI), 70 eV |
| Application Range | Trace-level quantitative and qualitative analysis of volatile and semi-volatile compounds |
| GC Oven | |
| Temperature Range | Ambient +5 °C to 450 °C |
| Ramp Rate | Up to 120 °C/min (method dependent) |
| Temperature Programming | Multi-step ramp/hold programming |
| Cooling | Fast cool-down with forced air circulation |
| Inlet | |
| Injection Type | Split / splitless capillary inlet |
| Maximum Temperature | Up to 400 °C |
| Pressure Control | Electronic Pneumatic Control (EPC) |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Injection Volume | 0.1 µL – 10 µL (method dependent) |
| Mass Spectrometer (TSQ 8000) | |
| Analyzer Type | Triple Quadrupole (QqQ) |
| Mass Range | m/z 10 – 1,050 |
| Scan Speed | Up to 20,000 u/sec |
| Acquisition Modes | Full Scan, SIM, SRM/MRM (MS/MS) |
| Sensitivity | Femtogram-level detection (compound and method dependent) |
| Dynamic Range | >10⁶ |
| Collision Cell | Pressurized collision cell for efficient fragmentation |
| Collision Gas | Argon (typical) |
| Detection System | Electron multiplier detector |
| SRM / MS/MS Performance | |
| Scan Type | Selected Reaction Monitoring (SRM) |
| Transitions | High-speed SRM with rapid dwell time optimization |
| Quantitation Capability | Ultra-trace quantitation with high selectivity |
| Noise Reduction | Advanced ion optics for reduced background interference |
| Autosampler (TriPlus 1310 AI/AS) | |
| Injection Mode | Automated liquid injection |
| Sample Capacity | Multi-position vial trays (configurable) |
| Injection Precision | <1% RSD (typical) |
| Carryover | Minimized via programmable wash cycles |
| Operation | Fully programmable sequences and workflows |
| Flow & Pneumatics | |
| Carrier Gas Control | Electronic Pneumatic Control (EPC) |
| Flow Modes | Constant flow, constant pressure, linear velocity |
| Gas Channels | Independent GC and MS gas control |
| Column Compatibility | |
| Column Type | Capillary GC columns |
| Length Range | Up to 100 m |
| Internal Diameter | 0.10 – 0.53 mm |
| Data & Control | |
| Software | Thermo Scientific Chromeleon CDS, TraceFinder |
| Data Acquisition | High-speed digital acquisition with MS/MS integration |
| Control Interface | PC-based instrument control |
| Physical | |
| System Configuration | Modular GC-MS/MS with external autosampler |
| Footprint | Benchtop system (multi-module) |
| Service Access | Front-access maintenance design |
| Construction | Modular architecture for scalability and serviceability |
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
-
Triple Quadrupole GC‑MS/MS Performance
Equipped with the TSQ 8000, this system delivers highly selective SRM/MRM analysis for accurate quantitation of trace compounds in complex matrices. -
Ultra-Low Detection Limits
Achieve sub‑ppb to femtogram-level sensitivity, enabling reliable detection of pesticides, VOCs, drugs, and contaminants at trace levels. -
Advanced Ion Optics & Noise Reduction
Optimized ion transmission and collision cell design reduce background interference, improving signal clarity and analytical confidence. -
Flexible TRACE 1310 GC Platform
Modular GC design supports multiple injectors and chromatographic configurations, allowing adaptation to diverse methods and workflows. -
Fast Oven Programming & Stable Retention Times
High ramp rates and precise EPC control deliver reproducible separations and shorter analysis cycles. -
Automated Sample Handling (TriPlus 1310 AI/AS)
Enhances lab productivity with programmable injection sequences, high capacity vial trays, and consistent injection precision. -
High Throughput & Workflow Efficiency
Designed for continuous operation in busy labs, with automation reducing manual intervention and human error. -
Comprehensive Software Integration
Compatible with Thermo Scientific platforms like Chromeleon and TraceFinder for method development, data acquisition, and compliance reporting. -
Robust Design for Regulated Environments
Suitable for EPA, FDA, and ISO-based applications requiring reproducibility, traceability, and audit readiness.
Applications
-
Environmental Testing
Detection of pesticides, herbicides, VOCs, SVOCs, and persistent organic pollutants (POPs) in soil, water, and air samples. -
Food Safety & Agriculture
Multi-residue pesticide screening, contaminant analysis, and food authenticity testing across complex food matrices. -
Pharmaceutical & Biopharma
Impurity profiling, residual solvent analysis (USP <467>), and quality control of APIs and finished products. -
Forensic & Toxicology
Identification and quantification of drugs, metabolites, and toxic substances in biological samples. -
Petrochemical & Chemical Analysis
Hydrocarbon profiling, fuel composition analysis, and additive detection in petrochemical workflows. -
Industrial & Material Testing
Monitoring volatile compounds, additives, and contaminants in polymers, coatings, and specialty chemicals.
User Manual – Thermo TRACE 1310 GC System
thermo-trace-1310-gc-user-manual
User Manual – Thermo TRACE 1310 GC System
thermo-tsq-8000_hardware-manual
Tune Reports – Thermo TSQ 8000 Triple Quad
tune-reports-thermo-8000-triple-quad
FAQ
A: A GC‑MS/MS system separates chemical compounds using gas chromatography and then identifies and quantifies them using tandem mass spectrometry, providing highly sensitive and selective analysis.
A: The TSQ 8000 uses a triple quadrupole design, enabling SRM/MRM analysis that significantly improves selectivity, reduces background noise, and achieves much lower detection limits compared to single quadrupole systems.
A: It is designed for volatile and semi-volatile compounds in matrices such as environmental samples, food products, pharmaceuticals, and biological fluids.
A: Yes, the TriPlus 1310 autosampler provides fully automated liquid injection, increasing throughput and improving reproducibility.
A: Detection limits can reach sub‑ppb to femtogram levels, depending on the compound, method, and matrix.
A: Yes, it is widely used in regulated laboratories and supports methods aligned with EPA, FDA, and ISO standards.
A: Environmental labs, food safety labs, pharmaceutical companies, forensic labs, and petrochemical industries commonly use this system.