Description
Thermo TRACE 1310 GC ECD with AI/AS 1310 Autosampler
Thermo TRACE 1310 GC ECD with AI/AS 1310 Autosampler system is configured for gas chromatography applications requiring sensitive detection of electronegative compounds and consistent automated sample handling. The system integrates an electron capture detector (ECD) with an automated injection platform to support reliable analytical workflows. The TRACE 1310 GC ECD with Autosampler utilizes an electron capture detector designed for trace-level detection of halogenated compounds and related analytes. The system includes a programmable oven for controlled temperature ramping and a precision inlet with electronic pressure control to maintain stable carrier gas flow. An integrated 1310 AI/AS autosampler enables automated liquid injection with consistent repeatability across sample sequences. Adjustable injection parameters support a range of analytical methods while reducing manual handling.
The TRACE 1310 GC ECD Autosampler is commonly used in environmental testing, chemical analysis, and laboratories requiring dependable low-level detection and reproducible chromatographic performance.
This Thermo TRACE 1310 GC ECD with AI/AS 1310 Autosampler is offered fully refurbished and tested, in working condition by Alliant Scientific.
Includes:
- Thermo Trace 1310 Gas Chromatograph (GC)
- Single Electron Capture Detectors (ECD)
- Single Split/Splitless Inlet (SSL)
- Thermo AI/AS 1310 Autosampler
- Data System
- 60-Day Warranty Coverage
Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer of the original manufacturer. Software, if included, is not transferable or upgradable. Alliant Scientific maintains the required licensing to legally distribute and transfer ECD instruments to qualified end users.
Technical Specifications
| General | |
|---|---|
| Instrument Type | Gas chromatograph (GC) |
| Model | TRACE 1310 |
| System Configuration | ECD detector with autosampler |
| Oven | |
| Temperature Range | Ambient +5 °C to 450 °C |
| Temperature Programming | Multi-step ramp control |
| Cooling | Forced-air rapid cool-down |
| Detector (ECD) | |
| Detector Type | Electron Capture Detector |
| Sensitivity | High sensitivity for electronegative compounds |
| Operating Temperature | Up to ~400 °C |
| Inlet | |
| Injection Type | Split / splitless |
| Pressure Control | Electronic pressure control (EPC) |
| Carrier Gas | Helium, hydrogen, or nitrogen |
| Autosampler | |
| Model | 1310 AI/AS |
| Injection Type | Automated liquid injection |
| Injection Volume | Typical 0.1–10 µL |
| Precision | High repeatability (low %RSD) |
| Flow & Pneumatics | |
| Flow Control | Electronic pressure control (EPC) |
| Flow Modes | Constant flow / constant pressure |
| Column Compatibility | |
| Column Type | Capillary columns |
| Column Range | 0.10–0.53 mm ID |
| Data & Control | |
| Software | Compatible with chromatography data systems (e.g., Chromeleon) |
| Control | Digital instrument control interface |
Additional information
| Availability | |
|---|---|
| Brand | |
| Model | |
| Onsite Installation | |
| Warranty | |
| Condition |
Key Features
- Electron Capture Detector (ECD) for sensitive detection of electronegative compounds
- High sensitivity for halogenated analytes and trace-level detection
- 1310 AI/AS autosampler for automated, repeatable liquid injection
- Split/splitless inlet with electronic pressure control for precise sample introduction
- Programmable oven with multi-step temperature ramping
- Stable carrier gas flow with electronic pressure control (EPC)
- Consistent and reproducible analytical performance
- Modular design for accessible components and simplified servicing
- Compatible with standard capillary GC columns
- Integrated control with chromatography data systems
Applications
- Environmental testing (pesticides, herbicides, contaminants)
- Detection of halogenated and electronegative compounds
- Chemical and industrial analysis
- Food safety and residue detection
- Trace-level analytical workflows
- Laboratory quality control and monitoring
- Research and method development
- Routine gas chromatography analysis
User Manual – Thermo TRACE 1310 GC System
FAQ
A: The system is equipped with an electron capture detector (ECD), designed for sensitive detection of electronegative compounds.
A: ECD is commonly used for halogenated compounds, pesticides, and other electronegative substances at low concentration levels.
A: Yes, it includes a 1310 AI/AS autosampler for automated liquid injection and improved repeatability.
A: The system typically supports split and splitless injection methods.
A: It is widely used in environmental testing, chemical analysis, food safety, and trace compound detection.
A: Yes, automated injection reduces manual handling and improves consistency across multiple samples.
A: Yes, it is well suited for both routine and specialized analysis requiring stable and consistent detection performance.






