Agilent 1260 Infinity II HPLC System with VWD, Vialsampler & Quaternary Pump

Agilent 1260 Infinity II HPLC System with VWD, Vialsampler & Quaternary Pump System is a modular liquid chromatography platform designed for reliable and reproducible analytical separations. This configuration includes a quaternary pump, autosampler, column compartment, and variable wavelength detector (VWD), enabling a complete workflow from solvent delivery to detection.

The integrated quaternary pump supports multi-solvent gradient formation, allowing flexible method development and compatibility with a wide range of analytical applications. The autosampler ensures consistent and precise sample introduction, supporting high-throughput laboratory environments.

The column compartment (MCT) maintains stable temperature conditions for chromatographic columns, which contributes to reproducibility and improved separation performance. The variable wavelength detector provides sensitive UV-visible detection across a range of wavelengths, making it suitable for routine and advanced analytical tasks.

Designed as part of the Infinity II series, this system supports modular expansion and seamless communication between components. It is commonly used in pharmaceutical, environmental, food safety, and chemical laboratories where consistent chromatographic performance is required.

This refurbished Agilent 1260 Infinity II HPLC System with VWD, Vialsampler & Quaternary Pump system has been fully tested and verified to be in proper working condition by Alliant Scientific

Includes:

  • Agilent 1260 Infinity II HPLC System
    • Solvent Tray
    • G7111B Quaternary Pump
    • G7129A Vialsampler
      • G7167-60101 Cooler
    • G7116A MCT
    • G7114A VWD
  • Data System
  • 90-Day Warranty Coverage

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

 

Technical Specifications

System Overview
Instrument Type High Performance Liquid Chromatography (HPLC) System
Series Agilent 1260 Infinity II
Configuration Modular LC system with pump, autosampler, column thermostat, and UV detector
Flow Control Method High-pressure reciprocating pump with active flow control
Solvent Delivery System (G7111B Quaternary Pump)
Pump Type Quaternary low-pressure gradient pump
Flow Rate Range 0.001 – 10 mL/min
Flow Precision < 0.1% RSD
Flow Accuracy ± 1% or 10 µL/min
Maximum Operating Pressure Up to 600 bar (6000 psi)
Solvent Channels 4-channel gradient blending
Degassing Integrated vacuum degassing system
Autosampler (G7129A Vialsampler)
Injection Type Automated vial-based injection
Injection Volume Range Typically 0.1 – 100 µL
Injection Precision < 0.5% RSD
Sample Capacity Multiple vial trays or microplates
Carryover Minimized through optimized needle wash system
Column Compartment (G7116A MCT)
Temperature Control Range Ambient to ~85°C
Temperature Stability ± 0.15°C
Column Capacity Multiple column positions with switching capability
Thermal Uniformity Forced-air circulation for consistent temperature distribution
Detector (G7114A Variable Wavelength Detector)
Detection Principle UV-Visible absorbance measurement
Wavelength Range 190 – 600 nm
Wavelength Accuracy ± 1 nm
Noise Level < 2.5 × 10⁻⁵ AU
Drift < 1 × 10⁻⁴ AU/hour
Flow Cell Analytical flow cell, low dispersion design
System Performance
Gradient Capability Multi-solvent gradient formation with programmable composition
Retention Time Precision < 0.1% RSD
Carryover Low carryover design for trace-level analysis
Peak Dispersion Optimized low dispersion flow path
Physical & Electrical
System Design Stackable modular architecture
Footprint Compact benchtop configuration
Power Requirements 100–240 V AC, 50/60 Hz
Operation Mode Continuous laboratory operation

Additional information

Availability

Brand

Condition

Model

, , ,

Onsite Installation

Warranty

Key Features

  • Complete HPLC system with pump, autosampler, column compartment, and detector
  • Quaternary pump for flexible solvent mixing and gradient methods
  • Automated sample injection for reproducible analysis
  • Temperature-controlled column compartment for stable separations
  • Variable wavelength detector for UV-visible analysis
  • Modular system design for easy expansion and configuration
  • Designed for analytical and routine laboratory workflows
  • Compatible with Agilent OpenLab software environment

Applications

  • Pharmaceutical analysis and quality control
  • Environmental testing and contaminant monitoring
  • Food and beverage safety analysis
  • Chemical compound separation and identification
  • Academic and research laboratory studies
  • Routine HPLC analytical workflows

Frequently Asked Questions

What does the Agilent 1260 Infinity II HPLC system do?

It performs liquid chromatography analysis by separating, detecting, and quantifying compounds within a sample.

What modules are included in this configuration?

This system includes a quaternary pump (G7111B), autosampler (G7129A), column compartment (G7116A), and variable wavelength detector (G7114A).

Is this system suitable for gradient methods?

Yes, the quaternary pump supports multi-solvent gradient formation, allowing flexible method development.

What type of detection does the VWD provide?

The variable wavelength detector provides UV-visible absorbance detection for quantitative and qualitative analysis.

Can the system be expanded?

Yes, the modular design allows additional components such as detectors or fraction collectors to be integrated.