Lease/Rent

Agilent 1200 Series HPLC System with Quaternary Pump and VWD

Listing #:LS-005646
Brand:Agilent
Model:G1311A, G1314C, G1316A, G1330B, G1367D, G1379B
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$15,500.00
In Stock
Make an Offer

Description

Agilent 1200 Series HPLC System Overview

This Agilent 1200 Series HPLC System is commonly used for routine analytical and quality control applications in laboratory environments. This configuration includes a quaternary solvent delivery system, high‑performance autosampler with temperature control, thermostatted column compartment, and variable wavelength UV detection.

The G1311A quaternary pump supports isocratic and low‑pressure gradient methods using up to four solvents, while an integrated vacuum degasser helps maintain stable baseline performance. Sample introduction is handled by the HiP‑ALS SL+ autosampler paired with an autosampler thermostat to allow controlled sample temperatures and consistent injection performance. Column temperature is regulated using a thermostatted column compartment to support reproducible chromatographic conditions. Detection is provided by a variable wavelength UV detector suitable for routine quantitative analysis.

This refurbished 1200 Series HPLC System with Quaternary Pump, HiP‑ALS SL+ & VWD System has been fully tested and verified to be in proper working condition by Alliant Scientific.

Includes:

  • Agilent 1200 HPLC system
    • Agilent 1200 G1379B Degasser
    • Agilent 1200 G1311A Quat Pump
    • Agilent 1200 G1367D Hip-Als SL+ Autosampler
    • Agilent 1200 G1330B FC/ALS Therm
    • Agilent 1260 G1316A TCC
    • Agilent 1200 G1314C VWD
    • Solvent Tray
  • Dell PC with Windows 11 Pro and Data System
  • 90 Day Warranty

Optional:

  • Premium refurbishment available with extended warranty options
  • Module Customization

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Technical Specifications

System Configuration
Degasser Agilent 1200 Series G1379B
Quaternary Pump Agilent 1200 Series G1311A
Autosampler Agilent 1200 Series G1367D High Performance ALS SL+
Autosampler Thermostat Agilent 1200 Series G1330B FC/ALS Thermostat
Column Compartment Agilent 1260 Series G1316A Thermostatted Column Compartment
Detector Agilent 1200 Series G1314C Variable Wavelength Detector (VWD SL)
Quaternary Pump (G1311A)
Flow Range Up to 10 mL/min
Maximum Pressure Up to 400 bar
Solvent Channels 4 (quaternary)
Gradient Type Low-pressure mixing
Autosampler (G1367D ALS SL+)
Injection Volume Range 0.1 – 100 µL
Injection Precision High-precision, variable volume injection
Sample Handling Temperature controlled with ALS thermostat
Column Compartment (G1316A)
Temperature Range 10 °C below ambient to 80 °C
Column Capacity Up to four analytical columns
Variable Wavelength Detector (G1314C)
Wavelength Range 190 – 600 nm
Detection Type UV absorbance, variable wavelength

Additional information

Availability

Brand

Condition

Model

, , , , ,

Onsite Installation

Warranty

Key Features

  • Quaternary solvent delivery system enabling flexible gradient and isocratic HPLC methods
  • Integrated vacuum degasser for stable baseline performance and reduced solvent outgassing
  • High‑performance autosampler (ALS SL+) supporting precise, repeatable injections
  • Autosampler thermostat for temperature‑controlled sample handling and improved reproducibility
  • Thermostatted column compartment providing stable column temperature control
  • Variable wavelength UV detector for reliable routine quantitative analysis
  • Proven Agilent 1200 Series platform with broad method compatibility
  • Suitable for routine analysis, quality control, and method development laboratories

APPLICATIONS 

  • Pharmaceutical quality control and routine release testing
  • Method development and validation workflows
  • Environmental and water analysis
  • Food and beverage quality testing
  • Chemical and academic research laboratories

 

FAQ

Q: Is this Agilent HPLC system suitable for routine QC laboratories?
A: Yes. This Agilent 1200 / 1260 Series configuration is commonly used for routine quality control, release testing, and general analytical workflows requiring reliable and reproducible HPLC performance.

Q: Does this system support gradient methods?
A: Yes. The G1311A quaternary pump supports low‑pressure gradient and isocratic methods using up to four solvents.

Q: What type of detector is included with this system?
A: This system is equipped with a variable wavelength UV detector (G1314C VWD SL), suitable for routine quantitative UV absorbance analysis.

Q: Is sample temperature control available?
A: Yes. The autosampler is paired with an autosampler thermostat (G1330B), allowing temperature‑controlled sample handling for improved reproducibility.

Q: Can column temperature be controlled independently?
A: Yes. The G1316A thermostatted column compartment provides stable column temperature control to support consistent retention times.

Q: Is this system compatible with Agilent ChemStation software?
A: Yes. This configuration is compatible with Agilent ChemStation software, subject to appropriate licensing and system setup.

Q: Can this system be upgraded or expanded later?
A: Yes. Additional detectors, valves, and accessories can be integrated depending on analytical requirements and compatibility.

Q: What is included with the system purchase?
A: The system includes the listed Agilent modules. Software licenses, columns, consumables, and accessories are typically not included unless specifically stated.