Lease/Rent

Agilent 6546A Q-TOF LC/MS System with 1260 Infinity II Front End

Listing #:LS-004817
Brand:
Model:6546A, G7111B, G7114A, G7116A, G7129A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$129,000.00
In Stock
Make an Offer

Agilent 6546A Q-TOF LC/MS System with 1260 Infinity II Front End — accurate-mass Q-TOF with a quaternary pump, cooled vialsampler, column thermostat, and variable wavelength detector for screening and impurity identification. Refurbished and tested by Alliant Scientific.

Description

Agilent 6546A Q-TOF LC-MS System with 1260 Infinity II Front End Overview

The Agilent 6546A Q-TOF LC-MS System with 1260 Infinity II Front End is a versatile accurate-mass system for laboratories that identify unknowns and confirm known compounds. The Q-TOF measures precursor and fragment masses with high resolution, so analysts can assign molecular formulas and distinguish compounds that a unit-mass instrument would confuse. The Dual AJS MultiMode source provides both electrospray and APCI, which broadens the range of molecules the system can ionize.

The 1260 Infinity II front end is built around a quaternary pump, which blends up to four solvents and speeds method development. A cooled vialsampler keeps samples stable through long overnight sequences, the multicolumn thermostat holds retention times consistent from run to run, and the variable wavelength detector records a single-wavelength UV trace alongside the mass spectra. Inside the Agilent 6546A Q-TOF LC-MS, the quadrupole selects precursor ions, the collision cell fragments them, and the time-of-flight analyzer measures each fragment’s mass from its flight time to the detector, giving the exact masses used for formula assignment.

Pharmaceutical QC and generic drug laboratories, peptide manufacturers, cannabis testing laboratories, food safety and contract testing labs, forensic toxicology and environmental laboratories use the Agilent 6546A Q-TOF LC-MS System for impurity identification, peptide characterization, contaminant screening and non-targeted analysis. For the same Q-TOF with a diode array detector and flexible pump, see the Agilent 6546 LC/Q-TOF with 1260 Infinity II HPLC.

This Agilent 6546A Q-TOF LC/MS System with 1260 Infinity II Front End is offered refurbished, fully tested, in working condition by Alliant Scientific.

Includes:

  • Agilent 6546A Q-TOF LC-MS(G6546A)
    • Dual AJS MultiMode Source (ESI + APCI)
    • Roughing Pump
  • Agilent 1260 Infinity II Front End
    • Solvent Tray
    • G7111B Quaternary Pump
    • G7129A Vialsampler
    • G7167-60101 Cooler
    • G7116A Multicolumn Thermostat (MCT)
    • G7114A Variable Wavelength Detector (VWD)
  • Data System
  • 90-Day Warranty

Browse our full LC-MS inventory for other Q-TOF and triple quadrupole systems.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
Mass Spectrometer 6546 LC/Q-TOF (G6546A)
Mass Analyzer Quadrupole, collision cell, time-of-flight (TOF)
Ion Source Dual AJS MultiMode source (ESI + APCI)
Acquisition MS and MS/MS, accurate mass
Software MassHunter, on the included data system
Vacuum System Roughing pump
LC System 1260 Infinity II front end
Pump (G7111B) Quaternary pump, up to 600 bar, integrated degasser
Autosampler (G7129A) Vialsampler, 132 × 2 mL vials
Sample Cooler (G7167-60101) Thermostatted sample cooling
Column Compartment (G7116A) Multicolumn thermostat, 10 °C below ambient to 85 °C
Detector (G7114A) Variable wavelength detector, 190 to 600 nm
Condition Refurbished and tested
Warranty 90 days

Additional information

Availability

Brand

Condition

Model

, , , ,

Onsite Installation

Warranty

Key Features

  • Q-TOF Accurate Mass – Exact precursor and fragment masses for molecular formula assignment.
  • ESI and APCI on One Source – Dual AJS MultiMode source covers polar and less polar compounds.
  • Quaternary Pump, 600 bar – Blends four solvents for faster method development.
  • Cooled 132-Vial Sampler – Keeps samples stable through overnight sequences.
  • Column Thermostat to 85 °C – Consistent retention times from batch to batch.
  • VWD, 190 to 600 nm – UV trace recorded alongside the mass spectra.
  • MassHunter Control – One workstation runs the LC and the mass spectrometer.

Applications

  • Pharmaceutical Impurity Identification – Generic drug manufacturers and QC laboratories identify unknown peaks in stability samples and confirm structures from accurate fragment masses.
  • Peptide Testing – Peptide manufacturers and QC laboratories confirm intact peptide mass, check sequence fragments and identify truncations, deletions and oxidation products.
  • Cannabis Testing – Cannabis testing laboratories screen products for pesticides, mycotoxins and unexpected contaminants, and characterize cannabinoids beyond a targeted panel.
  • Pesticide Residue Screening – Food safety and contract testing laboratories screen produce, grain and honey for hundreds of residues in a single run.
  • Forensic Toxicology – Toxicology laboratories run broad drug and metabolite screens on blood and urine, including compounds outside a targeted panel.
  • Emerging Environmental Contaminants – Environmental and water laboratories look for pharmaceuticals, industrial chemicals and pesticide transformation products in surface water and wastewater.
  • Food Authenticity – Food laboratories check olive oil, fruit juices and spices for marker compounds that reveal adulteration.

Frequently Asked Questions

What type of mass spectrometer is the Agilent 6546A Q-TOF LC/MS?

A quadrupole time-of-flight (Q-TOF) accurate-mass mass spectrometer.

Which ionization modes does the source support?

Electrospray (ESI) and APCI through the Dual AJS MultiMode source.

What HPLC front end is included?

A 1260 Infinity II with quaternary pump, cooled vialsampler, multicolumn thermostat and VWD.

How many vials does the vialsampler hold?

132 × 2 mL vials.

What UV detector is included?

A G7114A variable wavelength detector, 190 to 600 nm.

Which software controls the system?

Agilent MassHunter on the included data system.

What warranty does it have?

The system is refurbished and tested, and it ships with a 90-day warranty.