Wyatt DynaPro PlateReader II Dynamic Light Scattering Plate Reader WPR2‑08

Wyatt DynaPro PlateReader II Dynamic Light Scattering Plate Reader is a high-throughput analytical system designed for rapid characterization of macromolecules, proteins, and nanoparticles directly in microplate format. This advanced platform enables automated dynamic light scattering (DLS) measurements across multiple samples simultaneously, significantly increasing productivity compared to traditional single-sample DLS instruments.

Utilizing in-well measurements, the system eliminates the need for manual sample transfer and cuvette handling, allowing direct analysis in standard 96-, 384-, or 1536-well plates. This design streamlines workflows and supports high-throughput screening of formulation conditions, enabling efficient evaluation of particle size, aggregation, and stability across large sample sets. The DynaPro PlateReader II delivers sensitive and reproducible measurements of hydrodynamic radius, polydispersity, and molecular interactions in solution. Its capability to analyze very small sample volumes and perform rapid acquisition per well enables researchers to generate statistically robust datasets with minimal material consumption.

The system is optimized for applications requiring detailed insight into colloidal and thermal stability, including protein aggregation studies, biotherapeutic formulation development, and nanoparticle characterization. By combining automation with high-resolution light scattering detection, it provides a comprehensive solution for modern research laboratories focused on biomolecular and nanomaterial analysis.

This refurbished Wyatt DynaPro PlateReader II Dynamic Light Scattering Plate Reader WPR2‑08 is offered fully tested, in working condition by Alliant Scientific.

Includes:

  • Wyatt DynaPro PlateReader II
  • 30-Day Warranty Coverage

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Technical Specifications

  • Instrument type: Dynamic light scattering (DLS) plate reader
  • Model: DynaPro PlateReader II (WPR2-08)
  • Measurement technique: Dynamic light scattering (DLS) and optional static light scattering (SLS)
  • Sample format: 96-, 384-, and 1536-well microplates
  • Sample volume: As low as ~1.5–5 µL per well
  • Measurement speed: Approx. seconds per well acquisition
  • Particle size range: Sub-nanometer to micrometer scale (typical DLS range)
  • Parameters measured: Hydrodynamic radius, size distribution, aggregation, polydispersity
  • Additional outputs: Colloidal stability, thermal stability, molecular interactions
  • Temperature control: Integrated for stability and aggregation studies
  • Detection method: Laser-based light scattering
  • Throughput: High-throughput automated multi-sample analysis
  • Measurement mode: In situ well-based measurement (no transfer required)
  • Automation: Fully automated plate scanning and analysis
  • Data reproducibility: Supports replicate measurements across wells
  • Power requirements: 100–240 V, 50/60 Hz (per label)
  • Manufacture date: October 2017

Additional information

Availability

Brand

Condition

Onsite Installation

Warranty

Key Features

  • High-throughput dynamic light scattering system for rapid multi-sample analysis
  • Direct in-well measurement eliminates sample transfer and contamination risk
  • Supports 96-, 384-, and 1536-well plates for flexible throughput scaling
  • Accurate particle sizing and aggregation analysis in solution
  • Minimal sample volume requirements for cost-efficient workflows
  • Automated plate scanning for consistent and reproducible measurements
  • Fast acquisition times enable large dataset generation in a single run
  • Comprehensive stability analysis including thermal and colloidal behavior
  • Ideal for protein characterization, biologics development, and nanoparticle analysis
  • Reduces hands-on time compared to traditional cuvette-based DLS systems

Applications

  • Protein aggregation and stability studies
  • Biopharmaceutical formulation development
  • Nanoparticle and drug delivery characterization
  • Colloidal stability analysis of biomolecules
  • Screening buffer conditions for protein crystallization
  • Quality assessment of biologics and macromolecules
  • Structural biology and molecular interaction studies
  • High-throughput screening of formulations and conditions

Frequently Asked Questions

  • What does the DynaPro PlateReader II measure?
    It measures particle size, aggregation, and molecular interactions using dynamic light scattering.
  • How is this different from traditional DLS systems?
    It performs automated measurements in microplates, enabling high-throughput analysis without manual sample handling.
  • What sample formats are supported?
    Standard 96-, 384-, and 1536-well microplates are supported.
  • What types of samples can be analyzed?
    Proteins, nanoparticles, polymers, colloids, and other macromolecules in solution.
  • Why is high-throughput DLS important?
    It allows rapid screening of multiple conditions to optimize formulations and improve experimental efficiency.
  • Does it require large sample volumes?
    No, it requires very small volumes, typically a few microliters per well.