Lease/Rent

Agilent 1260 Infinity II HPLC System with G1364F Analytical Fraction Collector

Listing #:LS-006024
Brand:Agilent
Model:G1364F, G7111B, G7114A, G7116A, G7129A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$39,500.00
In Stock
Make an Offer

Description

Agilent 1260 Infinity II HPLC System with G1364F Analytical Fraction Collector

Configured with fraction collection capability for analytical HPLC workflows requiring automated sample isolation.

Agilent 1260 Infinity II HPLC System with G1364F Analytical Fraction Collector is a modular liquid chromatography platform configured with solvent delivery, automated sampling, temperature-controlled column management, UV detection, and analytical-scale fraction collection. This system enables complete chromatographic workflows from separation through detection and fraction isolation.

The Agilent G7111B Quaternary Pump provides controlled multi-solvent gradient formation, supporting method flexibility across a range of analytical applications. The autosampler enables reproducible sample introduction with low carryover, making the system suitable for both routine and high-throughput analysis. The multicolumn thermostat ensures stable thermal conditions for chromatographic columns, improving retention time consistency and separation performance. Detection is achieved using a G7114A VWD (Variable Wavelength UV-visible Detector) capable of monitoring absorbance across a defined spectral range. The integrated G1364F analytical-scale fraction collector extends system functionality by enabling automated collection of separated compounds. This component utilizes delay volume calibration to align fraction collection timing with chromatographic peak elution, supporting accurate sample isolation.

This refurbished Agilent 1260 Infinity II HPLC System with G1364F Analytical Fraction Collector has been fully tested and verified to be in proper working condition by Alliant Scientific

Includes:

  • Agilent 1260 Infinity II HPLC System
    • G7111B Quaternary Pump
    • G7129A Vialsampler
      • G7167-60101 Cooler
    • G7116A MCT
    • G7114A VWD
    • G1364F FC-AS Fraction Collector
  • Data System
  • 90-Day Warranty Coverage

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

 

Technical Specifications

System Configuration
Instrument Type High Performance Liquid Chromatography (HPLC) System with Fraction Collection
Series Agilent 1260 Infinity II
Configuration Modular LC system with pump, autosampler, thermostat, detector, and fraction collector
Flow Control Closed-loop flow control with reciprocating pump design
Solvent Delivery (G7111B Quaternary Pump)
Flow Rate Range 0.001 – 10 mL/min
Maximum Pressure Up to 600 bar (6000 psi)
Flow Precision < 0.1% RSD
Flow Accuracy ± 1% or 10 µL/min
Solvent Channels 4-channel gradient blending
Degassing Integrated vacuum degassing
Autosampler (G7129A Vialsampler)
Injection Volume Range 0.1 – 100 µL
Injection Precision < 0.5% RSD
Sample Capacity Vial trays and microplate formats
Carryover Low carryover via needle wash system
Column Compartment (G7116A MCT)
Temperature Range Ambient to ~85°C
Temperature Stability ± 0.15°C
Column Positions Multiple columns with switching capability
Thermal Control Forced-air uniform heating
Detector (G7114A VWD)
Detection Type UV-Visible absorbance
Wavelength Range 190 – 600 nm
Wavelength Accuracy ± 1 nm
Noise < 2.5 × 10⁻⁵ AU
Drift < 1 × 10⁻⁴ AU/hour
Fraction Collector (G1364F FC-AS)
Collection Type Analytical-scale automated fraction collection
Flow Compatibility ~100 µL/min to 10 mL/min
Collection Modes Time-based, peak-based, external trigger
Fraction Capacity Up to 216 vials or 384 well plates
Delay Calibration Automated delay volume sensing
Container Types Vials, tubes, SBS plates
System Performance
Gradient Formation Multi-solvent low-pressure gradient
Retention Time Precision < 0.1% RSD
System Dispersion Low internal volume optimized flow path
Electrical
Power Requirements 100–240 V AC, 50/60 Hz

Additional information

Availability

Brand

Condition

Model

, , , ,

Onsite Installation

Warranty

Key Features

  • Integrated HPLC system with full workflow capability including fraction collection
  • Quaternary pump for multi-solvent gradient flexibility
  • Autosampler with precise and reproducible injections
  • Temperature-controlled column compartment for stable separations
  • UV-visible detection via variable wavelength detector
  • Automated analytical-scale fraction collection system
  • Delay volume calibration ensures accurate fraction timing
  • Low dispersion system design for peak integrity
  • Modular architecture for scalable configurations

Applications

  • Pharmaceutical compound analysis and purification
  • Analytical and semi-preparative HPLC workflows
  • Biotechnology and life science research
  • Environmental testing and monitoring
  • Food safety and contaminant analysis
  • Chemical compound separation and fractionation

Frequently Asked Questions

What is this HPLC system used for?

It is used for chromatographic separation, detection, and collection of compounds in analytical workflows.

What does the fraction collector add to the system?

It allows automated collection of separated compounds, enabling purification and downstream analysis.

Is this system suitable for gradient methods?

Yes, the quaternary pump supports multi-solvent gradient formation.

What type of detection is used?

UV-visible absorbance detection using a variable wavelength detector.

What sample containers are compatible?

The system supports vials, tubes, and microtiter plates depending on configuration.