Agilent 1260 Infinity II G7162A Refractive Index Detector (RID)

Listing #:LS-006575
Brand:Agilent
Model:G7162A
Availability:In Stock
Condition:Refurbished
Warranty:30 Days
Onsite Installation:Available upon request
$11,500.00
In Stock
Make an Offer

Agilent 1260 Infinity II G7162A Refractive Index Detector (RID) — measures a 1.00–1.75 RIU range for non-UV absorbing compounds like carbohydrates, lipids, and polymers. Refurbished and tested by Alliant Scientific.

Listing last updated: September 2026

Description

Agilent 1260 Infinity II G7162A Refractive Index Detector (RID) Overview

The Agilent 1260 Infinity II G7162A Refractive Index Detector (RID) measures a refractive index range of 1.00 to 1.75 RIU with drift under 200 x 10⁻⁹ RIU/hr, making it well suited to detecting non-UV absorbing compounds such as carbohydrates, lipids, and polymers. Using electronic temperature control (ETC), it maintains a stable optical unit temperature up to 55°C, delivering consistent, reproducible results with minimal baseline drift.

The RID is a strong fit for gel permeation chromatography (GPC) and size exclusion chromatography (SEC) applications, where refractive index detection is essential for compounds lacking UV chromophores. An 8 µL sample cell with automatic purge and solvent recycle valves keeps operation efficient and minimizes solvent waste, while automatic light intensity adjustment compensates for lamp degradation and flow cell staining over time, reducing maintenance needs.

A maximum data rate of 74 Hz supports high-speed data acquisition even for narrow peaks, and the detector’s thermal design allows for fast start-up, typically ready to use within two hours of installation.

This Agilent 1260 Infinity II G7162A Refractive Index Detector (RID) is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 1260 Infinity II G7162A Refractive Index Detector (RID)
  • 30-Day Warranty

Looking for Other HPLC Detectors?

Browse our full HPLC inventory, or contact us to inquire about additional Agilent Infinity II detector modules.

Listing last updated: October 2026.

Technical Specifications

Manufacturer Agilent Technologies
Model 1260 Infinity II RID (G7162A)
Detection Type Refractive Index (deflection method)
Refractive Index Range 1.00 to 1.75 RIU, calibrated
Short-Term Noise < ± 1.25 x 10⁻⁹ RIU
Drift < 200 x 10⁻⁹ RIU/hr
Optics Temperature Control 5°C above ambient to 55°C
Sample Cell Volume 8 µL
Maximum Pressure 5 bar (0.5 MPa)
Maximum Flow Rate 5 mL/min
pH Range 2.3 – 9.5
Maximum Data Rate 74 Hz
Valves Automatic purge and automatic solvent recycle
Liquid Contact Materials 316 Stainless Steel, PTFE, Quartz Glass
Dimensions (H x W x D) 180 x 396 x 436 mm (7.1 x 15.6 x 17.2 in)
Weight 15 kg (33 lbs)
Power Requirements 100–240V, 50/60Hz, 70W/80VA
Condition Refurbished and tested
Warranty 30 days

Additional information

Availability

Brand

Condition

Model

Onsite Installation

Warranty

Key Features

  • Wide Refractive Index Range
    Measures 1.00 to 1.75 RIU with drift under 200 x 10⁻⁹ RIU/hr for stable, reliable readings.
  • Electronic Temperature Control (ETC)
    Maintains steady optical unit temperature up to 55°C for consistent, reproducible results.
  • Automatic Purge & Solvent Recycle
    Streamlines operation and minimizes solvent waste during routine use.
  • High-Speed Data Acquisition
    Maximum data rate of 74 Hz supports accurate detection of even narrow peaks.
  • Fast Start-Up
    Thermal design allows the detector to be ready for use within approximately two hours of installation.
  • Low-Maintenance Design
    Automatic light intensity adjustment compensates for lamp degradation and flow cell staining.

Applications

  • Carbohydrate Analysis
    Detection and quantification of sugars and other non-UV absorbing carbohydrates.
  • Polymer & Lipid Analysis
    Reliable detection of compounds lacking UV chromophores.
  • Gel Permeation Chromatography (GPC)
    Molecular weight distribution analysis of polymers.
  • Size Exclusion Chromatography (SEC)
    Separation and detection based on molecular size.

FAQ (Frequently Asked Questions)

What is a Refractive Index Detector (RID) used for?

An RID detects compounds that don’t absorb UV light — such as carbohydrates, lipids, and polymers — by measuring changes in refractive index as they pass through the flow cell, making it a key detector for GPC and SEC applications.

What refractive index range does this detector cover?

1.00 to 1.75 RIU, calibrated, with drift under 200 x 10⁻⁹ RIU/hr.

How long does this detector take to warm up?

Typically less than two hours for initial setup, with warm-up generally under one hour due to its thermal design.

Is this compatible with other 1260 Infinity II modules?

Yes — the G7162A is designed to integrate with the Agilent 1260/1290 Infinity II LC module family.

Does this unit include a warranty?

Yes — this unit ships with a 30-day warranty.