The Agilent 1260 Infinity G1329B Autosampler is a reliable and high-accuracy solution for automated sample introduction in HPLC systems. Built to support demanding analytical workflows, this module delivers consistent injection performance, minimal sample carryover, and flexible volume control, making it well-suited for regulated labs and research environments.

With a standard injection range from 0.1 µL up to 100 µL, and the ability to extend volumes to 1500 µL through multiple draw techniques, users can handle everything from trace-level analyses to higher-volume applications without compromising precision. The autosampler uses a continuous flow path architecture, ensuring that all wetted components remain within the liquid stream. This greatly reduces dead volume and helps maintain excellent peak integrity while limiting contamination between runs.

Designed to process up to 100 vials per sequence, the system supports automated workflows with features like overlapping injections and programmable cycles, improving throughput in busy laboratories. Additionally, optional temperature regulation allows safe handling of heat-sensitive samples between 4°C and 40°C when paired with a compatible thermostat. Delivering injection precision of better than 0.25% RSD, along with built-in diagnostics such as leak detection and maintenance tracking, the G1329B ensures both performance reliability and reduced downtime.

This refurbished Agilent Infinity G1329B Autosampler has been fully tested and verified to be in proper working condition by Alliant Scientific

Includes:

  • Agilent 1260 Infinity 1329B Autosampler
    • Power Cable
    • 30- Day Warranty Coverage

Optional:

  • Premium refurbishment available with extended warranty options

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Technical Specifications

Agilent 1260 Infinity G1329B Autosampler
Injection Volume Range 0.1 – 100 µL (standard), expandable up to 1500 µL with multi-draw capability
Injection Precision < 0.25% RSD (typical reproducibility)
Carryover < 0.1% typical; ≤ 0.05% with enhanced needle wash
Sample Capacity Up to 100 × 2 mL vials; 40 × 2 mL (half tray); 15 × 6 mL vials
Injection Cycle Time Approximately 50 seconds depending on method settings
Pressure Range Up to 600 bar (60 MPa)
Sample Viscosity Range 0.2 – 50 cP
Temperature Control Optional thermostat module, 4 – 40 °C range
Flow Path Design Continuous flow-through architecture for reduced dead volume
Dimensions (H × W × D) 200 × 345 × 435 mm (8 × 13.5 × 17 in)
Weight 14.2 kg (32 lb)
Power Requirements 100 – 240 V AC, 50/60 Hz
Connectivity CAN, RS232, and APG remote interfaces

Additional information

Availability

Brand

Condition

Model

Onsite Installation

Warranty

Key Features

High Precision Performance Delivers consistent injections with excellent reproducibility for analytical accuracy
Flexible Injection Volumes Supports micro-volume to high-volume injections for diverse HPLC applications
Low Carryover Design Minimizes sample contamination, ideal for trace-level and sensitive analyses
Large Sample Capacity Accommodates up to 100 vials to enable extended unattended operation
Flow-Through System Reduces dead volume and improves chromatographic performance
Automation Capabilities Includes overlapped injections and programmable sequences for higher throughput
Optional Temperature Control Maintains sample integrity for temperature-sensitive workflows
System Compatibility Integrates with Agilent 1100, 1200, and 1260 Infinity LC systems

Applications

Pharmaceutical Testing Supports drug development, quality control, and validation processes
Environmental Analysis Ideal for detecting contaminants in water, soil, and air samples
Food and Beverage Testing Ensures compliance with safety standards through precise compound analysis
Chemical Research Used in academic and industrial labs for method development and analysis
Biotechnology Enables reliable sample handling for biomolecules and complex mixtures

Frequently Asked Questions (FAQ)

What is the Agilent G1329B Autosampler used for? It automates sample injection in HPLC systems, improving accuracy, repeatability, and laboratory efficiency.
What injection volumes does this autosampler support? The standard range is 0.1 to 100 µL, with expansion up to 1500 µL using multi-draw functionality.
How many samples can it hold? The system can handle up to 100 vials depending on tray configuration.
Does it support temperature-sensitive samples? Yes, temperature regulation between 4°C and 40°C is available with an optional thermostat module.
Is the G1329B compatible with other Agilent systems? Yes, it integrates with Agilent 1100, 1200, and 1260 Infinity LC platforms.