Thermo Dionex ICS 5000 Chrome‑6 (Cr6) Analysis System with VWD Detector
Description
Thermo Dionex ICS 5000 Chrome‑6 (Cr6) Analysis System with VWD Detector Overview
Optimized for hexavalent chromium (Cr6) analysis using IC with post-column UV detection.
The Thermo Dionex ICS 5000 Chrome‑6 (Cr6) Analysis System with VWD Detector is configured for hexavalent chromium (Cr6) analysis using ion chromatography combined with post‑column derivatization and UV‑Vis detection. In this setup, chromium species are separated chromatographically and reacted post‑column to form a UV‑detectable complex, enabling selective and highly sensitive detection of Cr6 in environmental samples.
The system operates as a modular high‑pressure ion chromatography platform with Reagent‑Free IC (RFIC) functionality, generating eluents directly from deionized water. This ensures stable eluent concentration, minimizes operator variability, and supports reproducible results required for regulatory testing of drinking water, wastewater, and industrial samples.
The included ICS‑Series Variable Wavelength Detector (VWD) is critical for Cr6 workflows, providing UV‑Vis detection across a broad spectral range. Its dual‑lamp design and multi‑wavelength monitoring enable precise detection of post‑derivatized chromium complexes while maintaining low noise and stable baselines during extended analytical runs
This refurbished Thermo Dionex ICS 5000 Chrome‑6 (Cr6) Analysis System with VWD Detector has been fully tested and verified to be in proper working condition by Alliant Scientific.
Includes:
- Thermo Dionex ICS-5000 DC Detector
- Dual Conductivity Detector
- Thermo Dionex ICS-5000 DP Dual Pump
- Thermo Dionex VWD Detector
- Thermo Dionex AS-AP Autosampler
- PC loaded with Data System
- 60-Day Warranty Coverage
Options:
- Premium refurbishment available with extended warranty options
- Electrochemical Detectors available upon request.
Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.
Technical Specifications
| Dionex ICS-5000 System | |
| System Type | High-pressure ion chromatography (HPIC) |
| Maximum Pressure | Up to ~5000 psi |
| Eluent Generation | Reagent-Free IC (electrolytic) |
| Flow Formats | Capillary, microbore, analytical |
| Detector Compatibility | UV-Vis (VWD), conductivity, electrochemical |
| Temperature Control | Thermostatted modules for baseline stability |
| ICS-Series VWD Detector | |
| Detector Type | Variable Wavelength UV-Vis Detector |
| Wavelength Range | 190 – 900 nm |
| Wavelength Accuracy | ±1 nm |
| Bandwidth | 6 nm |
| Noise | < ±2.5 µAU (typical at 254 nm) |
| Drift | < 0.1 mAU/hr |
| Flow Cell | PEEK, ~11 µL volume |
| Lamps | Deuterium (UV) and Tungsten (visible) |
| Data Rate | Up to 10 Hz |
``
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
- Configured specifically for hexavalent chromium (Cr6) analysis using ion chromatography with post-column derivatization
- Enables selective UV detection of Cr6 via post-derivatized chromium complex
- ICS-5000 high-pressure ion chromatography platform (~5000 psi) for efficient separation of chromium species
- Reagent-Free Ion Chromatography (RFIC) with on-demand electrolytic eluent generation
- Eliminates manual eluent preparation, improving consistency in regulated testing environments
- ICS-Series Variable Wavelength Detector (VWD) designed for UV-based detection workflows
- Wide wavelength range (190–900 nm) supports Cr6 derivatization methods and other UV-active analytes
- Dual-lamp system (deuterium and tungsten) ensures stable signal across UV and visible ranges
- Low noise and low drift performance suitable for trace-level chromium detection
- PEEK flow path compatible with high-purity and trace metal analysis
- Supports integration with post-column derivatization modules for Cr6 methods
- Thermostatted system components maintain retention time and baseline stability during long analytical runs
Applications
- Hexavalent chromium (Cr6) analysis in drinking water and wastewater
- EPA Method 218.6 and 218.7 chromium (Cr6) compliance testing
- Environmental monitoring of trace chromium contamination
- Ion chromatography with post-column derivatization workflows
- Regulatory testing for municipal and industrial water systems
- Groundwater and surface water chromium analysis
- Organic acids and UV-active compound analysis using VWD detection
- Industrial corrosion and contamination studies involving chromium species
Frequently Asked Questions
What is this system designed for?
It is configured for hexavalent chromium (Cr6) analysis using ion chromatography with post-column derivatization and UV detection.
Why is a UV detector required for Cr6 analysis?
Cr6 is derivatized post-column to form a UV-active complex, which is then detected by the VWD.
Does the system use reagent-free ion chromatography?
Yes, RFIC automatically generates eluents from deionized water for consistent performance.
What samples can be analyzed?
Drinking water, wastewater, environmental samples, and industrial process samples.
Is this system suitable for regulatory testing?
Yes, it is widely used in environmental and compliance laboratories for trace Cr6 analysis.