Agilent 8890 GC with CTC Analytics PAL RSI 120 Autosampler
Related Gas Chromatography Systems
Explore additional systems in our gas chromatography category to compare Agilent GC platforms, detector configurations, autosampler options, and analytical solutions for environmental, petrochemical, pharmaceutical, food safety, and industrial applications.
Description
Agilent 8890 GC with CTC Analytics PAL RSI 120 Autosampler
Agilent 8890 GC with CTC Analytics PAL RSI 120 Autosampler is a high-performance gas chromatography system configured for automated liquid sample introduction and routine analytical workflows. Combining the advanced capabilities of the Agilent 8890 Gas Chromatograph with the precision and flexibility of the PAL RSI 120 robotic autosampler, this system is designed for laboratories requiring reliable chromatographic performance, high sample throughput, and consistent analytical results.
This configuration includes dual split/splitless (SSL) inlets and dual flame ionization detectors (FID), allowing simultaneous analysis using two analytical channels. The dual-channel design improves laboratory productivity by supporting multiple methods, columns, or sample streams within a single instrument platform.
The CTC Analytics PAL RSI 120 Autosampler provides automated liquid injection and sample handling while improving reproducibility and reducing operator variability. Widely used in environmental testing, petrochemical analysis, food and beverage quality control, pharmaceutical laboratories, and industrial chemical testing, the system is well suited for both routine QC testing and analytical method development.
This refurbished Agilent 8890 GC with CTC Analytics PAL RSI 120 Autosampler system has been fully tested and verified to be in proper working condition by Alliant Scientific.
Includes:
- Agilent 8890 GC
- Dual Split/Splitless Inlet (SSL)
- Dual Flame Ionization Detector (FID)
- CTC Analytics PAL RSI 120 Autosampler
- Injector
- 3 Drawer Cool Stack
- Wash Station
- Gameboy
- Power Supplies
- Tray Holder with Trays
- Data System
- Warranty Coverage
Disclaimer:Â All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.
Technical Specifications
| Gas Chromatograph | Agilent 8890 GC |
| Autosampler | CTC Analytics PAL RSI 120 |
| Inlet Configuration | 2 × Split/Splitless Inlets (SSL) |
| Detector Configuration | 2 × Flame Ionization Detectors (FID) |
| GC Oven Temperature Range | 4°C above ambient to 450°C |
| Maximum Oven Ramp Rate | Up to 120°C/min |
| Electronic Pneumatic Control | Standard EPC with digital pressure and flow control |
| Carrier Gas Compatibility | Helium, Hydrogen, Nitrogen, Argon/Methane |
| Maximum FID Temperature | 450°C |
| FID Detection Principle | Flame Ionization Detection |
| FID Typical Detection Limit | <1.2 pg Carbon/sec |
| Autosampler Model | PAL RSI 120 Robotic Sample Injector |
| Sample Capacity | Up to 120 Sample Vials |
| Injection Types | Automated Liquid Injection |
| Syringe Exchange Capability | User Configurable |
| Injection Volume Range | Application Dependent |
| Repeatability | High-precision robotic injection system |
| Automation Capability | Unattended Batch Processing |
| GC Dimensions (W × D × H) | Approx. 30 × 27 × 23 in (76 × 69 × 58 cm) |
| GC Weight | Approx. 120 lb (54 kg) |
| Power Requirements | 100–240 VAC, 50/60 Hz |
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
- Dual SSL Inlet Configuration
Provides flexibility for multiple analytical methods, column configurations, and sample types. - Dual FID Detection
Allows simultaneous chromatographic analysis with highly sensitive detection of organic compounds and hydrocarbons. - PAL RSI 120 Robotic Autosampler
Automates liquid sample introduction for improved reproducibility, throughput, and laboratory efficiency. - High-Speed GC Performance
Supports rapid oven heating and efficient chromatographic separations. - Automated Sample Processing
Reduces manual intervention and improves consistency between injections. - Flexible Analytical Platform
Suitable for environmental, petrochemical, food, pharmaceutical, and industrial testing applications.
Applications
- Hydrocarbon and fuel analysis
- Petrochemical quality control
- Environmental contaminant monitoring
- Volatile organic compound (VOC) analysis
- Residual solvent testing
- Food flavor and aroma analysis
- Food and beverage quality control
- Pharmaceutical raw material testing
- Chemical manufacturing quality assurance
- Method development and validation
FAQ
- What is the Agilent 8890 GC with CTC Analytics PAL RSI 120 used for?
The Agilent 8890 GC with CTC Analytics PAL RSI 120 is used for chromatographic analysis of volatile and semi-volatile compounds in environmental, petrochemical, food, pharmaceutical, and industrial laboratories. - How many detectors are installed on this Agilent 8890 GC?
This configuration includes two flame ionization detectors (FID). - How many inlets are included with the system?
The system is configured with two split/splitless (SSL) inlets. - What does the PAL RSI 120 Autosampler provide?
The PAL RSI 120 provides automated liquid injection and sample handling for improved throughput and injection reproducibility. - What types of compounds are commonly analyzed with FID detectors?
FID detectors are commonly used for hydrocarbons, solvents, fuels, petrochemicals, volatile organics, and other carbon-containing compounds. - What industries commonly use the Agilent 8890 GC platform?
The platform is widely used in environmental testing, petrochemical laboratories, food and beverage analysis, pharmaceutical research, and chemical manufacturing quality control.

















