Description
Agilent 8890 GC FID System with 7693 Autoinjector Tower Overview
This system is designed to deliver high-sensitivity detection of hydrocarbons and organic compounds, leveraging the proven performance of the FID with a wide linear dynamic range and excellent reproducibility. The single SSL inlet supports versatile injection techniques, ensuring compatibility across a broad range of analytical methods.
The inclusion of the Agilent 7693 Injector Tower enhances analytical precision by automating syringe positioning and injection processes. This reduces operator variability and improves consistency across runs, making it ideal for routine laboratory workflows and regulated environments. With advanced Electronic Pneumatic Control (EPC), the 8890 GC ensures stable gas flow regulation, while its fast oven ramping and thermal control support efficient separations. This configuration is particularly suited for laboratories seeking a balance of automation, sensitivity, and operational efficiency without a full autosampler tray system.
Agilent 8890 GC System is offered fully refurbished and tested, in working condition.
Includes:
- Agilent 8890A Gas Chromatograph (GC)
- Single Split/Splitless Inlet (SSL)
- Single Flame Ionization Detector (FID)
- Data System
- Agilent 7693 Series G4513A Autoinjector Tower
- 90- Day Warranty Coverage
Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.
Technical Specifications
| General | |
|---|---|
| Instrument Type | Gas Chromatograph (GC) |
| Model | Agilent 8890 GC |
| Configuration | Single FID, Single SSL Inlet with 7693 Injector Tower |
| Injector Module | Agilent 7693 Injector Tower (G4513A) |
| Application Range | Quantitative analysis of volatile and semi-volatile organic compounds |
| Inlet System | |
| Inlet Configuration | Single inlet |
| Inlet Type | Split / Splitless (SSL) |
| Temperature Range | Up to ~400°C (configuration dependent) |
| Control | Electronic Pneumatic Control (EPC) |
| Oven | |
| Temperature Range | Ambient +4°C to ~450°C |
| Ramp Programming | Multi-step programmable temperature gradients |
| Cooling | Forced-air cooling |
| Detector (FID) | |
| Type | Flame Ionization Detector (FID) |
| Detection Principle | Ionization of organic compounds in hydrogen-air flame |
| Sensitivity | High sensitivity to hydrocarbons (pg carbon level) |
| Dynamic Range | ~10^7 linear range |
| Ignition | Electronic ignition |
| Required Gases | Hydrogen, Air, Makeup gas (Nitrogen or Helium) |
| Injection Automation | |
| Injector Tower | G4513A |
| Injection Type | Automated liquid injection |
| Performance | High precision syringe alignment and injection reproducibility |
| Tray | Not included (injector tower only configuration) |
| Pneumatics | |
| Control System | Electronic pressure and flow control (EPC) |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| System Integration | |
| Software | Agilent OpenLab CDS (or equivalent) |
| Interfaces | LAN / standard instrument communication protocols |
| Physical | |
| Form Factor | Bench-top |
| Footprint | Compact GC system with injector module |
| Build | Designed for continuous laboratory operation |
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
- Agilent 8890 GC system with single FID for high-sensitivity hydrocarbon detection
- Single Split/Splitless (SSL) inlet for flexible sample introduction
- Agilent 7693 Injector Tower (G4513A) for automated, precise injections
- Improved reproducibility with reduced manual injection variability
- Wide linear dynamic range (~10^7) for accurate quantification
- Advanced Electronic Pneumatic Control (EPC) for precise gas flow management
- Fast oven ramping and stable temperature control
- Compact system footprint with modular expandability
- Compatible with Agilent OpenLab CDS for data acquisition and control
- Designed for routine laboratory and analytical workflows
Applications
- Hydrocarbon analysis in petrochemical laboratories
- Environmental VOC and organic compound testing
- Pharmaceutical quality control and impurity analysis
- Food and flavor compound characterization
- Chemical manufacturing and process monitoring
- Routine laboratory testing requiring reproducible injections
Operating Guide – Agilent 8890 GC System with 7693 ALS
agilent-8890-gc-operation-manual
agilent-7693-autosampler-installation-operation-maintanance-guide
Frequently Asked Questions (FAQ)
Does this system include a full autosampler?
No, this configuration includes the 7693 injector tower (G4513A) only and does not include the sample tray module.
What benefits does the injector tower provide?
The injector tower automates the injection process, improving precision, consistency, and reproducibility compared to manual injections.
What types of compounds can be analyzed?
The system is ideal for hydrocarbons and organic compounds, including VOCs and semi-volatile compounds.
Can this system be upgraded with a sample tray?
Yes, the system can be expanded with a compatible Agilent 7693 sample tray for full autosampler functionality.
What gases are required for operation?
The system requires carrier gas (helium, hydrogen, or nitrogen) along with hydrogen and air for FID operation.