Lease/Rent

Agilent 8890 GC FID System with 7693 Autoinjector Tower

Listing #:LS-005750
Brand:Agilent
Model:8890, G4513A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
In Stock

Description

Agilent 8890 GC FID System with 7693 Autoinjector Tower Overview

This system is designed to deliver high-sensitivity detection of hydrocarbons and organic compounds, leveraging the proven performance of the FID with a wide linear dynamic range and excellent reproducibility. The single SSL inlet supports versatile injection techniques, ensuring compatibility across a broad range of analytical methods.

The inclusion of the Agilent 7693 Injector Tower enhances analytical precision by automating syringe positioning and injection processes. This reduces operator variability and improves consistency across runs, making it ideal for routine laboratory workflows and regulated environments. With advanced Electronic Pneumatic Control (EPC), the 8890 GC ensures stable gas flow regulation, while its fast oven ramping and thermal control support efficient separations. This configuration is particularly suited for laboratories seeking a balance of automation, sensitivity, and operational efficiency without a full autosampler tray system.

Agilent 8890 GC System is offered fully refurbished and tested, in working condition.

 Includes:

  • Agilent 8890A Gas Chromatograph (GC)
    • Single Split/Splitless Inlet (SSL)
    • Single Flame Ionization Detector (FID)
    • Data System
  • Agilent 7693 Series G4513A Autoinjector Tower
    • 90- Day Warranty Coverage

 

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.

Technical Specifications

General
Instrument Type Gas Chromatograph (GC)
Model Agilent 8890 GC
Configuration Single FID, Single SSL Inlet with 7693 Injector Tower
Injector Module Agilent 7693 Injector Tower (G4513A)
Application Range Quantitative analysis of volatile and semi-volatile organic compounds
Inlet System
Inlet Configuration Single inlet
Inlet Type Split / Splitless (SSL)
Temperature Range Up to ~400°C (configuration dependent)
Control Electronic Pneumatic Control (EPC)
Oven
Temperature Range Ambient +4°C to ~450°C
Ramp Programming Multi-step programmable temperature gradients
Cooling Forced-air cooling
Detector (FID)
Type Flame Ionization Detector (FID)
Detection Principle Ionization of organic compounds in hydrogen-air flame
Sensitivity High sensitivity to hydrocarbons (pg carbon level)
Dynamic Range ~10^7 linear range
Ignition Electronic ignition
Required Gases Hydrogen, Air, Makeup gas (Nitrogen or Helium)
Injection Automation
Injector Tower G4513A
Injection Type Automated liquid injection
Performance High precision syringe alignment and injection reproducibility
Tray Not included (injector tower only configuration)
Pneumatics
Control System Electronic pressure and flow control (EPC)
Carrier Gas Options Helium, Hydrogen, Nitrogen
System Integration
Software Agilent OpenLab CDS (or equivalent)
Interfaces LAN / standard instrument communication protocols
Physical
Form Factor Bench-top
Footprint Compact GC system with injector module
Build Designed for continuous laboratory operation

Additional information

Availability

Brand

Condition

Model

,

Onsite Installation

Warranty

Key Features

  • Agilent 8890 GC system with single FID for high-sensitivity hydrocarbon detection
  • Single Split/Splitless (SSL) inlet for flexible sample introduction
  • Agilent 7693 Injector Tower (G4513A) for automated, precise injections
  • Improved reproducibility with reduced manual injection variability
  • Wide linear dynamic range (~10^7) for accurate quantification
  • Advanced Electronic Pneumatic Control (EPC) for precise gas flow management
  • Fast oven ramping and stable temperature control
  • Compact system footprint with modular expandability
  • Compatible with Agilent OpenLab CDS for data acquisition and control
  • Designed for routine laboratory and analytical workflows

Applications

  • Hydrocarbon analysis in petrochemical laboratories
  • Environmental VOC and organic compound testing
  • Pharmaceutical quality control and impurity analysis
  • Food and flavor compound characterization
  • Chemical manufacturing and process monitoring
  • Routine laboratory testing requiring reproducible injections

Frequently Asked Questions (FAQ)

Does this system include a full autosampler?

No, this configuration includes the 7693 injector tower (G4513A) only and does not include the sample tray module.

What benefits does the injector tower provide?

The injector tower automates the injection process, improving precision, consistency, and reproducibility compared to manual injections.

What types of compounds can be analyzed?

The system is ideal for hydrocarbons and organic compounds, including VOCs and semi-volatile compounds.

Can this system be upgraded with a sample tray?

Yes, the system can be expanded with a compatible Agilent 7693 sample tray for full autosampler functionality.

What gases are required for operation?

The system requires carrier gas (helium, hydrogen, or nitrogen) along with hydrogen and air for FID operation.