Lease/Rent

Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler

Listing #:LS-006273
Brand:Thermo Scientific
Model:Trace 1310, TriPlus 300, TSQ DUO
Availability:In Stock
Condition:Refurbished
Warranty:60 Days
Onsite Installation:Available upon request
$34,500.00
In Stock
Make an Offer

Browse our GC-MS/MS systems category to compare additional triple quadrupole mass spectrometers, automated sampling platforms, and analytical systems designed for quantitative and trace-level chemical analysis.

Description

Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler

Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler System is an integrated analytical platform designed for high-sensitivity analysis of volatile and semi-volatile compounds. Combining gas chromatography, triple quadrupole mass spectrometry, and automated headspace sampling, the system supports both routine quantitative testing and advanced trace-level investigations across a wide range of laboratory environments.

The TRACE 1310 Gas Chromatograph utilizes a split/splitless inlet configuration for flexible method development and efficient sample introduction. Detection is performed by the TSQ Duo Triple Quadrupole Mass Spectrometer, enabling targeted MS/MS workflows with enhanced selectivity and quantitative accuracy. The tandem quadrupole configuration helps reduce matrix interference while improving confidence in compound identification and confirmation.

The TriPlus 300 Master SHS Headspace Autosampler adds automated vial incubation, pressurization, and sample introduction for volatile compound analysis. By automating headspace workflows, the system improves reproducibility, increases sample throughput, and minimizes the variability associated with manual handling.

This configuration is commonly used for residual solvent analysis, VOC testing, environmental monitoring, food and beverage quality control, forensic toxicology, petrochemical characterization, and pharmaceutical impurity testing. The combination of triple quadrupole detection and headspace automation makes the platform particularly well suited for laboratories requiring reliable quantitative performance and consistent sample processing.

This Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler System is offered fully refurbished and tested, in working condition by Alliant Scientific.

Includes:

  • Thermo Trace 1310 GC
    • Split/Splitless Inlet (SSL)
  • Thermo TSQ Duo Triple Quad
  • Thermo TriPlus 300 Master SHS Headspace Autosampler
    • Headspace Sampling Module
    • Sample Tray(s)
  • Data System

Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler Specifications

Gas Chromatograph Thermo Scientific TRACE 1310 GC
Mass Spectrometer Thermo Scientific TSQ Duo Triple Quadrupole MS/MS
Autosampler Thermo TriPlus 300 Master SHS Headspace Autosampler
GC Inlet Configuration Single Split/Splitless (SSL)
GC Oven Temperature Range 4°C above ambient to 450°C
Maximum Oven Heating Rate Up to 120°C/min
Pressure Control Electronic Pressure Control (EPC)
Carrier Gases Helium, Hydrogen, Nitrogen
Mass Analyzer Type Triple Quadrupole
Ionization Mode Electron Ionization (EI)
Mass Range 10–1050 u
Mass Resolution Unit Resolution
Acquisition Modes Full Scan, SIM, SRM/MRM
Maximum Scan Speed Up to 20,000 u/sec
Headspace Sampling Method Static Headspace Sampling (SHS)
Autosampler Configuration Master SHS with Headspace Sampling Module
Supported Vial Sizes 10 mL and 20 mL Headspace Vials
Sample Capacity Up to 120 Vials (Configuration Dependent)
Incubation Temperature Range 40°C to 200°C
Transfer Line Temperature Up to 200°C
Syringe Heating Heated Syringe Assembly
Vacuum System Turbomolecular Vacuum Pump
GC Dimensions (W × D × H) 21 × 25 × 22 in (53 × 64 × 56 cm)
GC Weight Approx. 77 lb (35 kg)
MS Dimensions (W × D × H) 24 × 24 × 18 in (61 × 61 × 46 cm)
MS Weight Approx. 180 lb (82 kg)
Power Requirements 100–240 VAC, 50/60 Hz

Additional information

Availability

Brand

Condition

Model

, ,

Onsite Installation

Warranty

Key Features

  • Triple Quadrupole MS/MS Analysis
    Provides enhanced selectivity and compound confirmation through tandem mass spectrometry workflows.
  • Automated Headspace Sampling
    The TriPlus 300 SHS automates sample preparation and injection for volatile compound testing.
  • Selective Reaction Monitoring (SRM/MRM)
    Optimized for highly sensitive quantitative analysis in complex sample matrices.
  • Split/Splitless Injection Flexibility
    Supports a wide range of analytical methods and concentration ranges.
  • Integrated Analytical Workflow
    Combines gas chromatographic separation, tandem mass spectrometry, and automated headspace sampling in a single platform.
  • High Throughput Operation
    Designed for routine quantitative analysis and batch sample processing.

Applications

  • Residual solvent analysis
  • Volatile organic compound (VOC) testing
  • Environmental soil and water monitoring
  • Pesticide and herbicide residue analysis
  • Food flavor, aroma, and contaminant testing
  • Petrochemical and fuel composition analysis
  • Forensic toxicology investigations
  • Pharmaceutical impurity testing
  • Extractables and leachables analysis
  • Trace-level quantitative GC-MS/MS workflows

FAQ

  • What is the Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler used for?
    The system is used for quantitative and confirmatory analysis of volatile and semi-volatile compounds in environmental, pharmaceutical, food safety, forensic, and industrial laboratories.
  • Does the Thermo TRACE 1310 GC-MS/MS include a headspace autosampler?
    Yes. This configuration includes the Thermo TriPlus 300 Master SHS Headspace Autosampler with automated headspace sampling capability.
  • What advantages does the TSQ Duo Triple Quad provide?
    The TSQ Duo improves selectivity, sensitivity, and quantitative performance through tandem mass spectrometry and SRM/MRM acquisition methods.
  • What sample types are typically analyzed on the Thermo TRACE 1310 GC-MS/MS platform?
    The system is commonly used for solvents, fuels, environmental extracts, food products, pharmaceutical materials, and other volatile or semi-volatile compounds.
  • Why use a headspace autosampler with a GC-MS/MS system?
    Headspace sampling improves reproducibility and reduces sample contamination when analyzing volatile compounds.
  • What applications is the Thermo TRACE 1310 GC-MS/MS best suited for?
    Typical applications include residual solvents, VOCs, pesticide residues, contaminant monitoring, food safety analysis, and forensic investigations.