Description
Agilent 1200 HPLC System with Variable Wavelength Detector (VWD)
Agilent 1200 HPLC System with Variable Wavelength Detector is a reliable liquid chromatography platform designed to deliver consistent, high-quality analytical performance across routine and multi-method laboratory workflows.
This system is engineered to provide stable solvent delivery, precise sample introduction, controlled separation conditions, and sensitive UV detection within an integrated chromatographic setup. Its quaternary low-pressure gradient capability allows flexible solvent blending, supporting a broad range of analytical methods while simplifying method development and transfer. Consistent baseline performance and reproducibility are maintained through efficient solvent degassing and precise flow control, ensuring accurate quantification and reliable chromatographic results. Automated sampling combined with programmable sequences enables streamlined batch processing and reduced operator intervention, making the system well suited for high-throughput laboratory environments. Detection is performed using a Variable Wavelength Detector (VWD), providing selective and sensitive UV detection for compounds that absorb within the UV spectrum, making it ideal for routine quantitative applications.
This refurbished Agilent 1200 HPLC System has been fully tested and verified to be in proper working condition by Alliant Scientific.
Includes:
- Agilent 1200 HPLC System
- Solvent Tray
- G1379B Degasser
- G1311A Quaternary Pump
- G1367D Hip-ALS SL+ Autosampler
- G1316A TCC
- G1314C VWD SL
- Data System
- 90-Day Warranty Coverage
Optional:
- Premium refurbishment available with extended warranty options
- Module Customization
Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.
Technical Specifications
| Agilent 1200 HPLC System with VWD and HiP-ALS Autosampler | |
| System Configuration | Modular high-performance liquid chromatography (HPLC) system with quaternary gradient capability |
| Included Modules | G1379B Degasser, G1311A Quaternary Pump, G1367D HiP-ALS SL+ Autosampler, G1316A Column Compartment, G1314C Variable Wavelength Detector |
| Pump Type | Quaternary low-pressure gradient pump |
| Flow Rate Range | ~0.001 – 10 mL/min |
| Detection Method | UV variable wavelength detection |
| Wavelength Range | ~190 – 600 nm |
| Degassing | Integrated vacuum degasser (G1379B) |
| Sample Introduction | Automated injection via HiP-ALS autosampler |
| Column Compartment | Thermostatted column compartment with temperature control |
| Temperature Range | Ambient to ~80°C |
| Automation Features | Programmable sequences for unattended operation |
| Application Range | Pharmaceutical, environmental, food safety, and chemical analysis |
| Control Software | Compatible with Agilent OpenLab CDS |
| Power Requirements | 100 – 240 V, 50/60 Hz |
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
| Quaternary Pump Flexibility | Supports multi-solvent gradient formation for versatile analytical methods |
| Integrated Degassing | Removes dissolved gases to improve baseline stability and detector performance |
| UV Detection Sensitivity | Variable wavelength detector provides accurate compound quantification |
| High-Precision Autosampler | HiP-ALS SL+ ensures consistent injections and supports high-throughput workflows |
| Temperature Control | Column compartment maintains stable temperature for reproducible separations |
| Reliable Solvent Delivery | Stable and pulse-free flow improves chromatographic accuracy |
| Workflow Automation | Programmable sequences allow unattended operation |
| Software Integration | Compatible with Agilent OpenLab CDS for control and data analysis |
Applications
| Pharmaceutical Analysis | Quantification of APIs, impurities, and degradation products |
| Environmental Testing | Detection of contaminants in water and soil samples |
| Food and Beverage Testing | Analysis of additives, preservatives, and quality markers |
| Chemical Analysis | Separation and identification of compounds in mixtures |
| Quality Control Laboratories | Routine testing for product consistency and compliance |
| Research and Development | Method development and validation workflows |
Frequently Asked Questions (FAQ)
| What is this HPLC system used for? | It is used to separate, identify, and quantify compounds in liquid samples for routine laboratory analysis. |
| What is the benefit of the degasser? | The degasser removes dissolved gases from solvents, improving baseline stability and detector performance. |
| What advantage does the quaternary pump provide? | It allows flexible gradient mixing with multiple solvents for a wide range of analytical methods. |
| How does the autosampler improve workflow? | The HiP-ALS autosampler automates sample injection, ensuring consistent results and enabling unattended operation. |
| What type of detection is used? | The system uses a UV variable wavelength detector for sensitive compound detection and quantification. |
| What software controls the system? | The system is compatible with Agilent OpenLab CDS for full instrument control and data analysis. |