Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler
Browse our GC-MS/MS systems category to compare additional triple quadrupole mass spectrometers, automated sampling platforms, and analytical systems designed for quantitative and trace-level chemical analysis.
Description
Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler
Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler System is an integrated analytical platform designed for high-sensitivity analysis of volatile and semi-volatile compounds. Combining gas chromatography, triple quadrupole mass spectrometry, and automated headspace sampling, the system supports both routine quantitative testing and advanced trace-level investigations across a wide range of laboratory environments.
The TRACE 1310 Gas Chromatograph utilizes a split/splitless inlet configuration for flexible method development and efficient sample introduction. Detection is performed by the TSQ Duo Triple Quadrupole Mass Spectrometer, enabling targeted MS/MS workflows with enhanced selectivity and quantitative accuracy. The tandem quadrupole configuration helps reduce matrix interference while improving confidence in compound identification and confirmation.
The TriPlus 300 Master SHS Headspace Autosampler adds automated vial incubation, pressurization, and sample introduction for volatile compound analysis. By automating headspace workflows, the system improves reproducibility, increases sample throughput, and minimizes the variability associated with manual handling.
This configuration is commonly used for residual solvent analysis, VOC testing, environmental monitoring, food and beverage quality control, forensic toxicology, petrochemical characterization, and pharmaceutical impurity testing. The combination of triple quadrupole detection and headspace automation makes the platform particularly well suited for laboratories requiring reliable quantitative performance and consistent sample processing.
This Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler System is offered fully refurbished and tested, in working condition by Alliant Scientific.
Includes:
- Thermo Trace 1310 GC
- Split/Splitless Inlet (SSL)
- Thermo TSQ Duo Triple Quad
- Thermo TriPlus 300 Master SHS Headspace Autosampler
- Headspace Sampling Module
- Sample Tray(s)
- Data System
Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler Specifications
| Gas Chromatograph | Thermo Scientific TRACE 1310 GC |
| Mass Spectrometer | Thermo Scientific TSQ Duo Triple Quadrupole MS/MS |
| Autosampler | Thermo TriPlus 300 Master SHS Headspace Autosampler |
| GC Inlet Configuration | Single Split/Splitless (SSL) |
| GC Oven Temperature Range | 4°C above ambient to 450°C |
| Maximum Oven Heating Rate | Up to 120°C/min |
| Pressure Control | Electronic Pressure Control (EPC) |
| Carrier Gases | Helium, Hydrogen, Nitrogen |
| Mass Analyzer Type | Triple Quadrupole |
| Ionization Mode | Electron Ionization (EI) |
| Mass Range | 10–1050 u |
| Mass Resolution | Unit Resolution |
| Acquisition Modes | Full Scan, SIM, SRM/MRM |
| Maximum Scan Speed | Up to 20,000 u/sec |
| Headspace Sampling Method | Static Headspace Sampling (SHS) |
| Autosampler Configuration | Master SHS with Headspace Sampling Module |
| Supported Vial Sizes | 10 mL and 20 mL Headspace Vials |
| Sample Capacity | Up to 120 Vials (Configuration Dependent) |
| Incubation Temperature Range | 40°C to 200°C |
| Transfer Line Temperature | Up to 200°C |
| Syringe Heating | Heated Syringe Assembly |
| Vacuum System | Turbomolecular Vacuum Pump |
| GC Dimensions (W × D × H) | 21 × 25 × 22 in (53 × 64 × 56 cm) |
| GC Weight | Approx. 77 lb (35 kg) |
| MS Dimensions (W × D × H) | 24 × 24 × 18 in (61 × 61 × 46 cm) |
| MS Weight | Approx. 180 lb (82 kg) |
| Power Requirements | 100–240 VAC, 50/60 Hz |
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |
Key Features
- Triple Quadrupole MS/MS Analysis
Provides enhanced selectivity and compound confirmation through tandem mass spectrometry workflows. - Automated Headspace Sampling
The TriPlus 300 SHS automates sample preparation and injection for volatile compound testing. - Selective Reaction Monitoring (SRM/MRM)
Optimized for highly sensitive quantitative analysis in complex sample matrices. - Split/Splitless Injection Flexibility
Supports a wide range of analytical methods and concentration ranges. - Integrated Analytical Workflow
Combines gas chromatographic separation, tandem mass spectrometry, and automated headspace sampling in a single platform. - High Throughput Operation
Designed for routine quantitative analysis and batch sample processing.
Applications
- Residual solvent analysis
- Volatile organic compound (VOC) testing
- Environmental soil and water monitoring
- Pesticide and herbicide residue analysis
- Food flavor, aroma, and contaminant testing
- Petrochemical and fuel composition analysis
- Forensic toxicology investigations
- Pharmaceutical impurity testing
- Extractables and leachables analysis
- Trace-level quantitative GC-MS/MS workflows
FAQ
- What is the Thermo TRACE 1310 GC-MS/MS with TSQ Duo Triple Quad and TriPlus 300 Headspace Autosampler used for?
The system is used for quantitative and confirmatory analysis of volatile and semi-volatile compounds in environmental, pharmaceutical, food safety, forensic, and industrial laboratories. - Does the Thermo TRACE 1310 GC-MS/MS include a headspace autosampler?
Yes. This configuration includes the Thermo TriPlus 300 Master SHS Headspace Autosampler with automated headspace sampling capability. - What advantages does the TSQ Duo Triple Quad provide?
The TSQ Duo improves selectivity, sensitivity, and quantitative performance through tandem mass spectrometry and SRM/MRM acquisition methods. - What sample types are typically analyzed on the Thermo TRACE 1310 GC-MS/MS platform?
The system is commonly used for solvents, fuels, environmental extracts, food products, pharmaceutical materials, and other volatile or semi-volatile compounds. - Why use a headspace autosampler with a GC-MS/MS system?
Headspace sampling improves reproducibility and reduces sample contamination when analyzing volatile compounds. - What applications is the Thermo TRACE 1310 GC-MS/MS best suited for?
Typical applications include residual solvents, VOCs, pesticide residues, contaminant monitoring, food safety analysis, and forensic investigations.