This LC/Q‑TOF system is suitable for research, method development, regulated laboratory environments, system integration, service, or refurbishment, and is widely used in pharmaceutical, chemical, environmental, and life‑science laboratories.
Agilent 6546 LC/Q‑TOF Mass Spectrometer with Agilent 1290 Infinity II LC System
Description
This refurbished Agilent 6546 LC/Q‑TOF with Agilent 1290 Infinity II LC System has been fully tested and verified to be in proper working condition by Alliant Scientific
Includes:
- Agilent 6546 LC/Q‑TOF Mass Spectrometer
- Agilent 1290 Infinity II HPLC System
- Agilent 1290 Infinity II G7120A High‑Speed Pump
- Agilent 1290 Infinity II G7116B Multicolumn Thermostat (MCT)
- Agilent 1290 Infinity II G7167B Multisampler
- Agilent G7167‑60101 InfinityLab Sample Thermostat
- Agilent 1290 Infinity II G7117B Diode Array Detector (DAD)
- Agilent G3215A Mass Spectrometer Bench
- Agilent MS40+ RVP Roughing pump
- Dell PC with Windows 11 Pro and Data System
- 90 Day Warranty
Optional:
- Premium Refurbishment with Extended Warranty options
- Detector Options
Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. We are not an authorized dealer. Software, if included, is not transferable or upgradable.
Agilent 6546 LC/Q‑TOF Mass Spectrometer — Specifications
- Instrument Type: LC/MS
- Mass Analyzer: Quadrupole Time‑of‑Flight (Q‑TOF)
- Ionization Source: Electrospray Ionization (ESI)
- Acquisition Modes:
- Full‑scan accurate‑mass MS
- MS/MS (tandem mass spectrometry)
- Resolution: High‑resolution TOF analysis
- Mass Accuracy: High mass accuracy for confident compound identification
- Scan Speed: Fast acquisition suitable for UHPLC workflows
- Sensitivity: Optimized for trace‑level detection
- Software: Agilent MassHunter Workstation
- LC Compatibility: Agilent 1260 and 1290 Infinity / Infinity II LC systems
- Applications: Qualitative analysis, accurate‑mass identification, profiling, structural elucidation
Agilent 1290 Infinity II Front End System — Specifications
- System Type: UHPLC Front End
- Series: Agilent 1290 Infinity II
- Design: Modular UHPLC configuration
- Pressure Capability: UHPLC‑class high‑pressure operation
- Performance: High flow accuracy, low dispersion, and excellent reproducibility
- Integration: Designed for use with Agilent LC/MS and detector modules
- Software: Agilent OpenLab CDS
- Use Case: High‑speed, high‑resolution chromatographic separations
Agilent 1290 Infinity II G7120A High‑Speed Pump — Specifications
- Pump Type: Binary high‑pressure mixing pump
- Maximum Pressure: Up to 1300 bar
- Flow Accuracy: High precision and reproducibility
- Gradient Performance: Excellent gradient formation for fast separations
- Compatibility: UHPLC and fast‑LC methods
- Applications: High‑throughput UHPLC, LC/MS front‑end operation
Agilent 1290 Infinity II G7116B Multicolumn Thermostat (MCT) — Specifications
- Module Type: Column thermostat
- Function: Active column temperature control
- Capacity: Supports multiple LC columns
- Temperature Stability: High precision for reproducible retention times
- Heating/Cooling: Thermostatted environment (with thermostat option when configured)
- Applications: Method development, routine analysis, regulated workflows
Agilent 1290 Infinity II G7167B Multisampler
- Injection Precision: High repeatability for quantitative analysis
- Carryover: Low‑carryover design
- Throughput: Optimized for fast UHPLC workflows
- Pressure Capability: UHPLC‑compatible operation
- Automation: Fully automated liquid sampling
- Compatibility: Supports InfinityLab sample cooling and thermostat accessories
- Vial Handling: Designed for high‑density sample batches
Agilent G7167‑60101 InfinityLab Sample Thermostat — Specifications
- Accessory Type: Sample thermostat
- Function: Temperature control for LC sample vials
- Temperature Stability: Maintains consistent sample temperature
- Integration: Designed for use with Agilent InfinityLab autosamplers
- Purpose: Improves sample stability and reproducibility
- Applications: Temperature‑sensitive sample analysis
Agilent 1290 Infinity II G7117B Diode Array Detector (DAD) — Specifications
- Detector Type: Diode Array Detector (DAD)
- Model: G7117B
- Series: Agilent 1290 Infinity II
Optical & Detection
- Detection Method: UV‑Visible absorbance, diode array
- Wavelength Range: Broad UV‑Vis spectral coverage
- Data Acquisition: Full spectral acquisition for peak purity and identification
- Sensitivity: High sensitivity suitable for UHPLC workflows
- Baseline Stability: High stability for reproducible quantitative analysis
Performance
- Sampling Rate: High data acquisition speed compatible with fast UHPLC separations
- Linearity: Wide linear dynamic range
- Noise & Drift: Optimized for low noise and drift
Software Compatibility
- Agilent MassHunter LC/MS software
Typical Applications
- Pharmaceutical & biopharmaceutical analysis
- Impurity and degradation studies
- Metabolomics & lipidomics
- Proteomics & biomolecule characterization
- Environmental and food safety testing
Additional information
| Availability | |
|---|---|
| Brand | |
| Condition | |
| Model | |
| Onsite Installation | |
| Warranty |