Lease/Rent

Agilent 1100 HPLC System with VWD

Listing #:LS-004927
Brand:Agilent
Model:G1312A, G1313A, G1314A, G1316A, G1379A
Availability:In Stock
Condition:Refurbished
Warranty:90 Days
Onsite Installation:Available upon request
$8,500.00
In Stock
Make an Offer

Agilent 1100 HPLC System with VWD — G1312A binary pump, G1313A autosampler, G1316A column compartment and G1314A UV detector for routine HPLC. Refurbished and tested by Alliant Scientific.

Description

This Agilent 1100 HPLC VWD system is a complete liquid chromatography setup built around a G1312A binary pump, G1379A degasser, G1313A autosampler, G1316A thermostatted column compartment and G1314A variable wavelength detector (VWD).

The binary pump blends the degassed solvents and pushes them through the column, where the sample separates into its individual compounds. The VWD then records how much UV light each compound absorbs at the wavelength you select, which gives you the peaks you integrate and report.

The Agilent 1100 HPLC VWD system is a practical choice for laboratories that run UV-based methods every day and want proven hardware at a lower cost than a new instrument. The autosampler handles unattended sequences, and the column compartment keeps the temperature steady so retention times repeat from run to run.

Pharmaceutical QC groups, food and beverage labs, environmental testing labs and chemical manufacturers use this configuration for assays, impurity checks and routine release testing.

This Agilent 1100 HPLC VWD system is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Agilent 1100 HPLC System
    • G1379A Vacuum Degasser
    • G1312A Binary Pump
    • G1313A Autosampler (ALS)
    • G1316A Thermostatted Column Compartment (TCC)
    • G1314A Variable Wavelength Detector (VWD)
  • Solvent Tray
  • Data System
  • 90-Day Warranty

Compare this Agilent 1100 HPLC VWD system with other configurations in our full HPLC inventory, including 1100 and 1200 Series systems with different pumps and detectors.

Disclaimer: All brand names and trademarks are the property of their respective owners and are used for identification only. The seller is not authorized by or associated with Agilent. This product has not been reviewed, tested, or certified by Agilent to verify its quality or compatibility with Agilent’s products. Software, if included, is not transferable or upgradable.

Listing last updated: November 2026.

Technical Specifications

Manufacturer Agilent Technologies
System 1100 Series HPLC, modular
Degasser (G1379A) Vacuum degasser
Pump (G1312A) Binary pump
Flow Range 0.001 to 5.0 mL/min, 0.001 mL/min increments
Pressure Range 0 to 400 bar (5,880 psi)
Flow Precision Below 0.3% RSD (typically below 0.15% RSD)
Delay Volume 180 to 480 µL (600 to 900 µL with mixer), depending on back pressure
Autosampler (G1313A) Automatic liquid sampler, 100 µL metering head
Injection Volume 0.1 to 100 µL in 0.1 µL increments
Injection Precision Typically below 0.5% RSD of peak area (5 to 100 µL)
Carryover Typically below 0.1%
Vial Capacity 100 x 2 mL vials
Column Compartment (G1316A) Peltier-controlled thermostatted column compartment, below-ambient and above-ambient operation
Detector (G1314A) Variable wavelength detector (VWD)
Wavelength Range 190 to 600 nm
Flow Cell Standard 14 µL, 10 mm path length, 40 bar
Data System Included
Condition Refurbished and tested
Warranty 90 days

Additional information

Brand

Condition

Model

, , , ,

Onsite Installation

Warranty

Availability

Key Features

  • 0.001 to 5.0 mL/min Binary Pump
    Binary gradients at up to 400 bar for routine analytical columns.
  • Flow Precision Below 0.3% RSD
    Steady flow keeps retention times consistent run to run.
  • 190 to 600 nm VWD
    Single-wavelength UV detection across the full UV range.
  • 100-Vial Autosampler
    Injections from 0.1 to 100 µL for unattended sequences.
  • Low Carryover
    Typically below 0.1% between injections.
  • Peltier Column Compartment
    Holds column temperature above and below ambient.
  • Vacuum Degasser
    Removes dissolved gas for a quieter baseline.
  • Complete Setup
    Solvent tray and data system come with the system.

Applications

  • Pharmaceutical QC
    Assay, impurity and dissolution testing.
  • Food and Beverage Testing
    Vitamins, preservatives, sweeteners and dyes.
  • Environmental Analysis
    Pesticides and contaminants in water and soil extracts.
  • Chemical Manufacturing
    Purity checks and routine QC on raw materials and products.
  • Teaching Laboratories
    Straightforward gradient HPLC for training.

FAQ (Frequently Asked Questions)

What type of pump does this system have?

A G1312A binary pump, which mixes two solvents for gradient or isocratic runs.

What is the flow range and pressure limit?

0.001 to 5.0 mL/min, up to 400 bar.

What wavelength range does the VWD cover?

190 to 600 nm.

What injection volumes does the autosampler handle?

0.1 to 100 µL.

How many vials does the autosampler hold?

100 x 2 mL vials.

Does this system include a warranty?

Yes — it ships with a 90-day warranty.