Lease/Rent

Waters Acquity bio-Sample Manager-FTN 186015040

Listing #:LS-007001
Brand:Waters
Model:Acquity bio-Sample Manager-FTN 186015040, Acquity CH-A 186015042
Availability:In Stock
Condition:Refurbished
Warranty:30 Days
Onsite Installation:Available upon request
$3,950.00
In Stock
Make an Offer

Waters Acquity bio-Sample Manager-FTN 186015040 — flow-through needle autosampler for UPLC H-Class Bio systems with 4 to 40 °C sample cooling, 768-sample capacity, and CH-A column heater included. Refurbished and tested by Alliant Scientific.

Description

Waters Acquity bio-Sample Manager-FTN Overview

The Waters ACQUITY UPLC bio-Sample Manager-FTN (part number 186015040) is a temperature-controlled autosampler with a flow-through needle (FTN) design for ACQUITY UPLC H-Class Bio systems. It is built with a biocompatible flow path for biopharmaceutical applications.

Injection volume ranges from 0.1 to 10.0 µL in 0.1 µL increments as standard, and up to 1,000 µL with optional extension loops. Precision is better than 1% RSD from 0.2 to 1.9 µL and better than 0.5% RSD from 2.0 to 10.0 µL. The direct-injection flow path minimizes dispersion, carryover is below 0.004% (caffeine, UV), and the integral needle wash is active and programmable.

The sample compartment is settable from 4 to 40 °C in 0.1 °C increments. It holds any two plates for a capacity of 768 samples in two 384-well plates or 96 samples in 2 mL vial holders, plus four additional positions for dilution. An optional Sample Organizer expands capacity to 7,296 samples in nineteen 384-well plates. Auto-dilution, auto-addition, and load-ahead are supported, and the minimum sample required is 3 µL residual using total recovery.

This unit includes the Waters Acquity UPLC CH-A Column Heater (186015042). The CH-A holds a single column up to 150 mm long and 4.6 mm I.D. and heats from 20 °C (or 5 °C above ambient) to 90 °C with active pre-heating of the incoming mobile phase.

This Waters Acquity bio-Sample Manager-FTN is offered fully refurbished and tested, in working condition, by Alliant Scientific.

Includes:

  • Waters Acquity UPLC bio-Sample Manager-FTN (186015040)
  • Waters Acquity UPLC CH-A Column Heater with Active Pre-Heating (186015042)
  • 30-Day Warranty

Listing last updated: October 2026.

Technical Specifications

Manufacturer Waters
Model ACQUITY UPLC bio-Sample Manager-FTN (186015040)
Injection Design Flow-through needle (FTN), biocompatible flow path
Injection Volume Range 0.1 to 10.0 µL (0.1 µL increments); up to 1,000 µL with optional extension loops
Injection Precision < 1% RSD (0.2 to 1.9 µL); < 0.5% RSD (2.0 to 10.0 µL)
Sample Carryover < 0.004% (caffeine, UV)
Needle Wash Integral, active, programmable
Sample Plates Any two plates; 768 samples in two 384-well plates or 96 in 2 mL vial holders, plus 4 dilution positions
Maximum Sample Capacity 7,296 samples in nineteen 384-well plates (with optional Sample Organizer)
Sample Compartment Temperature 4.0 to 40.0 °C, settable in 0.1 °C increments
Minimum Sample Required 3 µL residual, using total recovery
Advanced Capabilities Auto-dilution, auto-addition, load-ahead
Included Column Heater ACQUITY UPLC CH-A (186015042)
Column Capacity Single column, up to 150 mm length, 1.0 to 4.6 mm I.D., with filter or guard column
Column Temperature Range 20 °C (or 5 °C above ambient, whichever is higher) to 90 °C
Column Temperature Accuracy and Stability ± 0.5 °C accuracy; ± 0.3 °C stability at sensor
Solvent Conditioning Active pre-heating
Compatible Systems ACQUITY UPLC H-Class Bio
Condition Refurbished and tested
Warranty 30 days

Additional information

Availability

Brand

Condition

Model

,

Onsite Installation

Warranty

Key Features

  • Flow-Through Needle Design
    Direct injection minimizes dispersion and carryover for precise, low-carryover injections.
  • Biocompatible Flow Path
    Built for biopharmaceutical applications on ACQUITY UPLC H-Class Bio systems.
  • Temperature-Controlled Samples
    Sample compartment settable from 4 to 40 °C in 0.1 °C increments.
  • Flexible Sample Capacity
    768 samples in two 384-well plates, or 96 in 2 mL vial holders, with up to 7,296 using a Sample Organizer.
  • Wide Injection Range
    0.1 to 10.0 µL as standard, and up to 1,000 µL with optional extension loops.
  • Advanced Sample Handling
    Auto-dilution, auto-addition, and load-ahead capabilities.
  • CH-A Column Heater Included
    Active pre-heating column heater controls column temperature up to 90 °C.

Applications

  • Biopharmaceutical Analysis
    Peptide, protein, and biologic characterization on bio-compatible UPLC systems.
  • High-Throughput Screening
    384-well plate capacity with load-ahead for fast injection cycles.
  • Method Development
    Auto-dilution and auto-addition automate sample preparation steps.
  • Routine QC
    Low carryover and precise injections for repeatable results across batches.

FAQ (Frequently Asked Questions)

Does this unit include the column heater?

Yes — it includes the Waters Acquity UPLC CH-A Column Heater (186015042) with active pre-heating.

What injection volumes does the sample manager support?

0.1 to 10.0 µL as standard, and up to 1,000 µL with optional extension loops.

How many samples can it hold?

768 samples in two 384-well plates, or 96 in 2 mL vial holders. An optional Sample Organizer expands capacity to 7,296 samples.

Can the sample compartment be cooled?

Yes — the compartment is settable from 4 to 40 °C in 0.1 °C increments.

Which systems is it compatible with?

ACQUITY UPLC H-Class Bio systems.

Does this unit include a warranty?

Yes — this unit ships with a 30-day warranty.